XPG Core Reactor II 1200W PSU Review – Platinum > Gold

Load Regulation

Test 12V 5V 3.3V 5VSB DC/AC (Watts) Efficiency Fan Speed (RPM) PSU Noise (dB[A]) Temps (In/Out) PF/AC Volts
10% 8.134A 1.98A 1.964A 0.993A 119.989 87.023% 394 <6.0 40.36C 0.972
12.096V 5.049V 3.36V 5.038V 137.883 44.64C 114.87V
20% 17.316A 2.971A 2.948A 1.192A 239.948 90.903% 394 <6.0 40.60C 0.982
12.072V 5.049V 3.359V 5.034V 263.964 45.20C 114.84V
30% 26.782A 3.466A 3.44A 1.392A 359.16 91.574% 394 <6.0 41.35C 0.981
12.064V 5.049V 3.358V 5.03V 392.211 46.38C 114.79V
40% 36.355A 3.961A 3.932A 1.592A 479.546 91.574% 395 <6.0 41.82C 0.984
12.057V 5.049V 3.357V 5.027V 523.666 47.35C 114.75V
50% 45.541A 4.951A 4.917A 1.791A 599.314 91.18% 396 <6.0 42.38C 0.987
12.051V 5.05V 3.356V 5.025V 657.291 48.46C 114.71V
60% 54.795A 5.94A 5.901A 1.991A 719.854 90.524% 431 <6.0 42.70C 0.99
12.046V 5.051V 3.356V 5.023V 795.199 49.22C 114.65V
70% 63.996A 6.931A 6.888A 2.191A 839.567 89.782% 761 20.7 43.46C 0.992
12.039V 5.051V 3.354V 5.02V 935.12 50.49C 114.61V
80% 73.279A 7.922A 7.877A 2.292A 959.588 88.882% 1108 32.2 44.15C 0.993
12.032V 5.049V 3.352V 5.017V 1079.637 52.25C 114.55V
90% 82.894A 8.419A 8.358A 2.394A 1079.377 87.951% 1483 41.3 44.71C 0.994
12.026V 5.047V 3.35V 5.013V 1227.244 53.73C 114.51V
100% 92.320A 8.917A 8.87A 3A 1199.421 86.863% 1949 48.8 45.82C 0.994
12.020V 5.046V 3.349V 5V 1380.804 55.89C 114.46V
110% 101.684A 9.912A 9.953A 3.001A 1320.007 85.836% 2161 50.4 47.32C 0.995
12.015V 5.044V 3.346V 4.999V 1537.836 58.26C 114.41V
CL1 0.116A 14.297A 14.24A 0A 121.306 81.955% 398 <6.0 40.97C 0.975
12.103V 5.049V 3.35V 5.089V 148.016 46.45C 114.86V
CL2 0.116A 21.729A 0A 0A 111.314 80.427% 397 <6.0 41.89C 0.974
12.107V 5.059V 3.361V 5.11V 138.404 48.92C 114.87V
CL3 0.116A 0A 21.671A 0A 74.007 75.123% 395 <6.0 42.35C 0.964
12.057V 5.062V 3.351V 5.071V 98.515 51.38C 114.89V
CL4 99.806A 0A 0A 0A 1199.965 87.563% 1802 46.6 45.56C 0.994
12.023V 5.063V 3.364V 5.041V 1370.415 56.54C 114.47V

Load regulation is tight on all rails, especially at 5VSB, which sets a record. Not that this rail is so important in load regulation, but it is always good to see it having low voltage drops.

Ripple Suppression

Test 12V 5V 3.3V 5VSB Pass/Fail
10% Load 8.1 mV 8.0 mV 7.6 mV 8.8 mV Pass
20% Load 13.5 mV 8.9 mV 8.7 mV 9.7 mV Pass
30% Load 10.5 mV 7.7 mV 7.8 mV 8.4 mV Pass
40% Load 10.1 mV 8.3 mV 8.3 mV 8.3 mV Pass
50% Load 9.8 mV 12.0 mV 14.4 mV 12.0 mV Pass
60% Load 9.8 mV 7.7 mV 8.0 mV 8.1 mV Pass
70% Load 11.8 mV 8.0 mV 8.9 mV 9.5 mV Pass
80% Load 10.8 mV 8.6 mV 9.6 mV 9.1 mV Pass
90% Load 11.1 mV 7.5 mV 9.0 mV 8.9 mV Pass
100% Load 17.2 mV 9.8 mV 11.1 mV 9.4 mV Pass
110% Load 17.7 mV 9.5 mV 12.3 mV 9.6 mV Pass
Crossload 1 9.4 mV 9.8 mV 11.0 mV 7.6 mV Pass
Crossload 2 12.1 mV 18.5 mV 8.6 mV 7.7 mV Pass
Crossload 3 47.3 mV 7.8 mV 16.0 mV 7.5 mV Pass
Crossload 4 16.0 mV 7.6 mV 10.5 mV 8.4 mV Pass

CWT’s platforms are usually ripple-proof, which is the case here.