1st Player NGDP 1300W PSU Review

Hold Up Time

The hold-up time is long, and the power ok signal is accurate. The 1000W unit has the same bulk caps as the 1300W, hence its extra-long hold-up time.

Inrush Current

The inrush current is high at 230V. I should point out here that we changed the methodology in our inrush current testing, using new equipment, which allows for more accurate results.

Timings

The PSU supports Alternative Low Power Modes.