1st Player NGDP 1300W PSU Review

Load Regulation

Test 12V 5V 3.3V 5VSB DC/AC (Watts) Efficiency Fan Speed (RPM) PSU Noise (dB[A]) Temps (In/Out) PF/AC Volts
10% 8.876A 2.004A 1.963A 1.004A 129.993 90.351% 1381 33.5 40.52C 0.972
12.211V 4.99V 3.362V 4.98V 143.882 44.71C 114.87V
20% 18.764A 3.009A 2.948A 1.207A 259.947 92.176% 1300 31.9 40.72C 0.982
12.206V 4.984V 3.358V 4.973V 282.014 45.29C 114.82V
30% 28.974A 3.513A 3.441A 1.409A 389.608 92.519% 1384 33.6 41.45C 0.989
12.203V 4.982V 3.356V 4.967V 421.177 46.48C 114.81V
40% 39.212A 4.016A 3.936A 1.613A 519.538 92.401% 1493 35.8 41.74C 0.993
12.199V 4.98V 3.354V 4.961V 562.268 47.23C 114.74V
50% 49.134A 5.024A 4.924A 1.816A 649.7 91.924% 1755 40.1 42.30C 0.995
12.195V 4.976V 3.351V 4.957V 706.787 48.29C 114.7V
60% 59.061A 6.033A 5.915A 2A 779.725 91.356% 1873 42.2 42.83C 0.996
12.191V 4.973V 3.348V 4.953V 853.506 49.42C 114.64V
70% 68.994A 7.043A 6.907A 2.223A 909.911 90.632% 1976 43.4 43.16C 0.996
12.187V 4.97V 3.345V 4.948V 1003.97 50.21C 114.59V
80% 78.933A 8.052A 7.9A 2.325A 1039.532 89.875% 2098 44.7 43.98C 0.997
12.183V 4.967V 3.342V 4.946V 1156.638 52.02C 114.54V
90% 89.273A 8.559A 8.385A 2.428A 1169.767 89.044% 2177 45.6 44.97C 0.997
12.179V 4.965V 3.339V 4.942V 1313.697 54.03C 114.48V
100% 99.359A 9.066A 8.9A 3.043A 1299.376 88.173% 2184 45.8 45.33C 0.997
12.174V 4.963V 3.337V 4.929V 1473.668 55.39C 114.43V
110% 109.384A 10.08A 9.989A 3.044A 1429.594 87.151% 2189 45.8 46.63C 0.996
12.170V 4.96V 3.334V 4.928V 1640.369 57.56C 114.37V
CL1 0.115A 14.551A 14.29A 0A 121.305 83.413% 1847 41.8 40.45C 0.972
12.208V 4.961V 3.338V 5.038V 145.424 45.91C 114.86V
CL2 0.113A 20.157A 0A 0.001A 101.343 82.843% 1432 34.7 39.18C 0.967
12.210V 4.959V 3.355V 5.056V 122.32 46.24C 114.87V
CL3 0.113A 0A 19.765A 0A 67.4 77.865% 1431 34.7 39.71C 0.952
12.211V 4.984V 3.34V 4.991V 86.563 48.75C 114.89V
CL4 106.763A 0A 0.001A 0.001A 1300.016 88.605% 2179 45.6 44.55C 0.997
12.176V 4.983V 3.354V 4.957V 1467.186 55.53C 114.44V

Load regulation is generally tight, especially at 12V, the rail that matters the most!

Ripple Suppression

Test 12V 5V 3.3V 5VSB Pass/Fail
10% Load 13.1 mV 9.1 mV 11.0 mV 12.7 mV Pass
20% Load 13.3 mV 10.4 mV 11.9 mV 13.1 mV Pass
30% Load 12.2 mV 9.3 mV 11.0 mV 12.2 mV Pass
40% Load 15.0 mV 11.2 mV 13.9 mV 14.2 mV Pass
50% Load 16.2 mV 11.6 mV 15.3 mV 14.2 mV Pass
60% Load 18.4 mV 12.7 mV 18.1 mV 16.4 mV Pass
70% Load 18.7 mV 12.8 mV 20.5 mV 17.6 mV Pass
80% Load 20.9 mV 15.3 mV 23.8 mV 18.4 mV Pass
90% Load 22.9 mV 17.4 mV 25.3 mV 19.6 mV Pass
100% Load 33.9 mV 18.1 mV 27.7 mV 23.2 mV Pass
110% Load 36.2 mV 20.6 mV 29.5 mV 24.8 mV Pass
Crossload 1 19.7 mV 12.6 mV 16.6 mV 15.4 mV Pass
Crossload 2 13.7 mV 18.5 mV 12.8 mV 15.8 mV Pass
Crossload 3 11.9 mV 8.1 mV 18.0 mV 11.9 mV Pass
Crossload 4 33.7 mV 15.7 mV 24.2 mV 20.2 mV Pass

Ripple suppression is good in most rails but not competitive since the competition is crazy in this section. In any case, below 35mV ripple at 12V under full load and above 47C is a pretty good performance. Only the 3,3V rail needs improvement here.

Pages ( 4 of 11 ): « Previous123 4 567891011Next »

Related Posts

Leave a Reply

Your email address will not be published. Required fields are marked *