Thermaltake Toughpower GF A3 1200W PSU Review

Load Regulation

Test 12V 5V 3.3V 5VSB DC/AC (Watts) Efficiency Fan Speed (RPM) PSU Noise (dB[A]) Temps (In/Out) PF/AC Volts
10% 8.211A 1.985A 1.967A 0.983A 119.975 88.802% 0 <6.0 44.46°C 0.978
11.981V 5.038V 3.355V 5.088V 135.104 40.24°C 114.83V
20% 17.450A 2.978A 2.955A 1.182A 239.922 91.406% 1340 32.2 40.85°C 0.978
11.979V 5.036V 3.35V 5.077V 262.481 45.38°C 114.8V
30% 26.988A 3.476A 3.453A 1.382A 359.08 92.093% 1342 32.3 41.09°C 0.984
11.969V 5.034V 3.345V 5.065V 389.909 46.17°C 114.75V
40% 36.637A 3.975A 3.95A 1.583A 479.447 92.038% 1345 32.7 41.57°C 0.988
11.962V 5.032V 3.342V 5.054V 520.921 47.12°C 114.71V
50% 45.894A 4.972A 4.941A 1.784A 599.191 91.567% 1350 33.2 42.29°C 0.991
11.955V 5.029V 3.339V 5.043V 654.374 48.26°C 114.66V
60% 55.219A 5.97A 5.934A 1.987A 719.729 90.631% 1354 33.7 42.82°C 0.993
11.951V 5.025V 3.337V 5.033V 794.129 49.33°C 114.63V
70% 64.496A 6.969A 6.931A 2.19A 839.434 89.864% 1358 33.8 43.14°C 0.994
11.944V 5.022V 3.333V 5.021V 934.11 50.18°C 114.57V
80% 73.842A 7.971A 7.924A 2.294A 959.442 88.843% 1822 42.2 43.71°C 0.995
11.939V 5.019V 3.331V 5.013V 1079.934 51.75°C 114.52V
90% 83.545A 8.471A 8.414A 2.398A 1079.279 87.873% 2146 44.5 44.16°C 0.996
11.931V 5.016V 3.327V 5.003V 1228.221 53.19°C 114.47V
100% 93.058A 8.975A 8.932A 3.009A 1199.322 86.729% 2751 51.8 45.34°C 0.996
11.924V 5.014V 3.325V 4.984V 1382.853 55.39°C 114.42V
110% 102.516A 9.978A 10.025A 3.014A 1319.891 85.584% 2751 51.8 46.65°C 0.997
11.916V 5.011V 3.321V 4.976V 1542.218 57.49°C 114.37V
CL1 0.115A 11.975A 11.854A 0A 101.283 82.281% 1355 33.8 40.32°C 0.972
11.984V 5.027V 3.349V 5.106V 123.094 45.72°C 114.83V
CL2 0.115A 19.907A 0A 0A 101.352 80.833% 1358 33.8 40.59°C 0.972
11.979V 5.022V 3.36V 5.107V 125.385 47.65°C 114.83V
CL3 0.115A 0A 19.727A 0A 67.376 75.956% 1343 32.4 40.37°C 0.964
11.989V 5.038V 3.346V 5.103V 88.706 49.38°C 114.85V
CL4 100.666A 0A 0A 0A 1199.885 87.619% 2343 47.8 45.96°C 0.996
11.919V 5.026V 3.33V 5.044V 1369.456 56.89°C 114.43V

Load regulation is only tight enough on the minor rails, but I would like to see within 1% at 12V.

Ripple Suppression

Test 12V 5V 3.3V 5VSB Pass/Fail
10% Load 5.2 mV 8.9 mV 8.7 mV 5.3 mV Pass
20% Load 16.3 mV 9.1 mV 8.8 mV 5.5 mV Pass
30% Load 15.7 mV 9.0 mV 8.8 mV 5.7 mV Pass
40% Load 13.9 mV 9.4 mV 8.8 mV 6.4 mV Pass
50% Load 14.3 mV 9.3 mV 9.9 mV 6.9 mV Pass
60% Load 13.2 mV 9.7 mV 9.3 mV 7.2 mV Pass
70% Load 12.3 mV 8.8 mV 8.3 mV 8.1 mV Pass
80% Load 15.1 mV 9.3 mV 9.6 mV 9.0 mV Pass
90% Load 16.9 mV 9.7 mV 9.8 mV 9.5 mV Pass
100% Load 20.3 mV 12.3 mV 13.4 mV 13.4 mV Pass
110% Load 24.9 mV 12.9 mV 14.7 mV 13.6 mV Pass
Crossload 1 6.1 mV 10.7 mV 10.4 mV 6.9 mV Pass
Crossload 2 6.2 mV 12.2 mV 6.8 mV 6.3 mV Pass
Crossload 3 6.7 mV 9.8 mV 11.1 mV 6.4 mV Pass
Crossload 4 18.2 mV 10.2 mV 11.2 mV 11.6 mV Pass

Ripple suppression is good on all rails.