Enermax Revolution D.F.12 850W PSU Review

Load Regulation

Test 12V 5V 3.3V 5VSB DC/AC (Watts) Efficiency Fan Speed (RPM) PSU Noise (dB[A]) Temps (In/Out) PF/AC Volts
10% 5.233A 2.01A 1.999A 0.984A 85.008 88.735% 0 <6.0 44.49C 0.977
12.116V 4.977V 3.302V 5.083V 95.8 40.48C 115.16V
20% 11.482A 3.018A 3.005A 1.184A 169.979 91.136% 0 <6.0 45.01C 0.985
12.112V 4.971V 3.295V 5.071V 186.51 40.67C 115.14V
30% 18.081A 3.526A 3.513A 1.384A 254.99 91.713% 916 27.1 41.18C 0.991
12.108V 4.965V 3.288V 5.059V 278.034 45.95C 115.11V
40% 24.694A 4.033A 4.023A 1.586A 340.081 91.709% 916 27.1 41.76C 0.993
12.103V 4.96V 3.281V 5.047V 370.824 46.79C 115.09V
50% 30.956A 5.048A 5.042A 1.788A 425.097 91.272% 916 27.1 42.28C 0.994
12.100V 4.954V 3.273V 5.034V 465.745 47.82C 115.07V
60% 37.186A 6.066A 6.065A 1.992A 509.632 90.51% 1245 33.7 42.77C 0.994
12.097V 4.947V 3.265V 5.021V 563.068 48.79C 115.04V
70% 43.483A 7.086A 7.093A 2.197A 594.964 89.614% 1609 41.5 43.19C 0.994
12.093V 4.941V 3.257V 5.008V 663.921 50.21C 115.02V
80% 49.786A 8.109A 8.126A 2.301A 679.808 88.822% 1863 44.6 43.77C 0.995
12.089V 4.933V 3.249V 4.998V 765.358 51.86C 114.99V
90% 56.493A 8.626A 8.637A 2.406A 765.264 88% 2091 47.2 44.48C 0.995
12.086V 4.928V 3.242V 4.988V 869.614 53.54C 114.96V
100% 62.931A 9.146A 9.183A 3.023A 850.078 86.993% 2175 47.6 45.42C 0.994
12.082V 4.921V 3.234V 4.962V 977.18 55.51C 114.93V
110% 69.241A 10.177A 10.324A 3.028A 934.666 85.855% 2173 47.6 46.75C 0.994
12.079V 4.914V 3.225V 4.954V 1088.655 57.69C 114.92V
CL1 0.116A 12.14A 12.107A 0A 101.318 83.701% 921 27.2 40.46C 0.978
12.112V 4.959V 3.279V 5.104V 121.048 45.98C 115.15V
CL2 0.116A 20.184A 0A 0A 101.407 81.995% 932 27.7 40.58C 0.978
12.113V 4.954V 3.3V 5.109V 123.675 47.61C 115.15V
CL3 0.116A 0A 20.181A 0A 67.398 77.349% 914 27.0 40.07C 0.978
12.108V 4.974V 3.27V 5.102V 87.138 49.16C 115.16V
CL4 70.352A 0A 0A 0A 849.798 87.788% 2183 47.7 45.23C 0.994
12.080V 4.94V 3.257V 5.062V 968.017 56.19C 114.94V

Load regulation is tight at 12V, which matters most, but loose on the rest rails.

Ripple Suppression

Test 12V 5V 3.3V 5VSB Pass/Fail
10% Load 7.7 mV 7.4 mV 4.6 mV 8.3 mV Pass
20% Load 8.2 mV 7.9 mV 5.0 mV 9.3 mV Pass
30% Load 9.9 mV 9.3 mV 6.1 mV 10.5 mV Pass
40% Load 11.2 mV 10.2 mV 6.8 mV 10.3 mV Pass
50% Load 12.8 mV 10.5 mV 7.3 mV 11.4 mV Pass
60% Load 14.9 mV 10.9 mV 8.3 mV 11.9 mV Pass
70% Load 16.0 mV 12.0 mV 9.4 mV 12.5 mV Pass
80% Load 16.1 mV 13.9 mV 13.2 mV 13.6 mV Pass
90% Load 17.2 mV 13.8 mV 14.1 mV 16.1 mV Pass
100% Load 23.8 mV 15.4 mV 15.6 mV 18.2 mV Pass
110% Load 25.1 mV 17.3 mV 16.2 mV 20.9 mV Pass
Crossload 1 15.3 mV 15.0 mV 12.7 mV 20.3 mV Pass
Crossload 2 11.0 mV 16.9 mV 7.7 mV 19.9 mV Pass
Crossload 3 13.7 mV 11.9 mV 14.8 mV 17.6 mV Pass
Crossload 4 20.6 mV 10.5 mV 10.6 mV 16.4 mV Pass

Ripple suppression is good on all rails.