Protection Features
OCP (Cold @ 27°C) | 12V: 125.6A (150.78%), 11.901V 5V: 35A (140%), 5.009V 3.3V: 36.3A (145.2%), 3.212V 5VSB: 5.7A (190%), 4.812V |
OCP (Hot @ 44°C) | 12V: >118.8A (>142.62%), <11.928V 5V: 34.7A (138.8%), 5.017V 3.3V: 30.4A (121.6%), 3.233V 5VSB: 5.6A (186.67%), 4.801V |
OPP (Cold @ 27°C) | 1468.32W (146.83%) |
OPP (Hot @ 43°C) | 1408.31W (140.83%) |
OTP | – |
SCP | – |
PWR_OK | Proper operation |
NLO | ✓ |
Fan Failure Protection | ✗ |
SIP | Surge: MOV Inrush: NTC Thermistor & Bypass relay |
The 12V OCP triggering points are set high, and the same goes for the OPP ones. The PSU didn’t start after I finished the OPP (Hot) evaluation, so I couldn’t proceed with OTP and SCP evaluations. The hot OPP triggering point needs to drop, and in my opinion, the cold one also needs to drop lower.