Corsair TX1000 ATX v3.1 PSU Review

Load Regulation

Test 12V 5V 3.3V 5VSB DC/AC (Watts) Efficiency Fan Speed (RPM) PSU Noise (dB[A]) Temps (In/Out) PF/AC Volts
10% 6.526A 1.985A 1.993A 0.992A 100.027 84.383% 0 <6.0 44.49°C 0.971
12.016V 5.04V 3.311V 5.044V 118.54 40.22°C 115.13V
20% 14.084A 2.978A 2.995A 1.195A 199.988 88.883% 0 <6.0 45.35°C 0.977
12.005V 5.038V 3.306V 5.021V 225 40.81°C 115.1V
30% 22.006A 3.477A 3.498A 1.399A 300.048 90.169% 0 <6.0 46.25°C 0.987
11.996V 5.035V 3.302V 5.006V 332.766 41.23°C 115.08V
40% 29.942A 3.977A 4.005A 1.605A 399.839 90.175% 987 32.5 41.75°C 0.991
11.977V 5.03V 3.296V 4.985V 443.401 47.29°C 115.05V
50% 37.533A 4.975A 5.014A 1.814A 499.564 89.947% 1059 34.3 42.46°C 0.994
11.964V 5.027V 3.291V 4.962V 555.4 48.47°C 115.02V
60% 45.199A 5.973A 6.027A 2.001A 600.006 89.443% 1165 37.0 42.73°C 0.996
11.954V 5.024V 3.286V 4.941V 670.821 49.4°C 114.99V
70% 52.805A 6.973A 7.043A 2.238A 699.856 88.803% 1285 39.7 43.31°C 0.997
11.945V 5.021V 3.281V 4.917V 788.098 50.37°C 114.96V
80% 60.496A 7.972A 8.06A 2.349A 799.886 87.963% 1389 41.8 43.74°C 0.997
11.934V 5.018V 3.275V 4.896V 909.349 51.89°C 114.94V
90% 68.529A 8.475A 8.561A 2.466A 899.665 87.199% 1503 44.6 44.76°C 0.998
11.925V 5.016V 3.271V 4.867V 1031.738 53.85°C 114.91V
100% 76.377A 8.978A 9.093A 3.12A 999.701 86.32% 1623 45.7 45.73°C 0.998
11.915V 5.013V 3.266V 4.808V 1158.123 55.8°C 114.87V
110% 84.169A 9.982A 10.213A 3.116A 1100.326 85.348% 1755 47.5 46.82°C 0.998
11.905V 5.01V 3.26V 4.815V 1289.236 57.7°C 114.83V
CL1 0.116A 15.557A 15.698A 0A 131.309 79.779% 0 <6.0 47.48°C 0.974
12.024V 5.034V 3.287V 4.955V 164.573 41.41°C 115.13V
CL2 0.116A 24.871A 0A 0A 126.402 78.198% 0 <6.0 47.4°C 0.973
12.026V 5.026V 3.318V 5.081V 161.642 41.28°C 115.13V
CL3 0.116A 0A 25.254A 0A 83.898 70.869% 0 <6.0 43.11°C 0.972
12.029V 5.05V 3.267V 5.077V 118.386 41.06°C 115.14V
CL4 83.853A 0A 0A 0A 1000.202 87.017% 1620 45.7 45.84°C 0.998
11.928V 5.03V 3.288V 5.001V 1149.419 56.27°C 114.88V

Load regulation should be tighter in general, especially at 12V and 3.3V.

Ripple Suppression

Test 12V 5V 3.3V 5VSB Pass/Fail
10% Load 11.7 mV 6.3 mV 4.2 mV 6.7 mV Pass
20% Load 13.9 mV 6.1 mV 4.4 mV 6.9 mV Pass
30% Load 12.3 mV 7.0 mV 4.5 mV 7.1 mV Pass
40% Load 11.9 mV 6.7 mV 4.6 mV 8.2 mV Pass
50% Load 12.6 mV 7.7 mV 4.9 mV 7.5 mV Pass
60% Load 14.0 mV 7.5 mV 5.1 mV 8.0 mV Pass
70% Load 15.6 mV 9.9 mV 7.6 mV 9.3 mV Pass
80% Load 16.5 mV 10.5 mV 8.8 mV 12.1 mV Pass
90% Load 16.8 mV 9.3 mV 8.4 mV 11.0 mV Pass
100% Load 22.9 mV 10.3 mV 8.7 mV 13.1 mV Pass
110% Load 24.6 mV 10.4 mV 8.7 mV 14.7 mV Pass
Crossload 1 20.9 mV 8.9 mV 8.7 mV 5.9 mV Pass
Crossload 2 13.0 mV 6.4 mV 3.9 mV 5.7 mV Pass
Crossload 3 42.4 mV 6.9 mV 10.1 mV 5.5 mV Pass
Crossload 4 23.6 mV 9.9 mV 5.5 mV 8.5 mV Pass

Ripple suppression is good.

Pages ( 4 of 11 ): « Previous123 4 567891011Next »

Related Posts

2 thoughts on “Corsair TX1000 ATX v3.1 PSU Review

Leave a Reply

Your email address will not be published. Required fields are marked *

Please consider turning off your adblocker to support our work! We work night and day to offer quality content, and ads help us continue our work! Thank you! The Hardware Busters Team