Cooler Master V1300 SFX Platinum – The STRONGEST SFX PSU!

Load Regulation

Test 12V 5V 3.3V 5VSB DC/AC (Watts) Efficiency Fan Speed (RPM) PSU Noise (dB[A]) Temps (In/Out) PF/AC Volts
10% 8.973A 1.965A 1.957A 0.983A 130.027 88.681% 1594 26.1 40.59C 0.818
12.084V 5.09V 3.373V 5.086V 146.619 44.82C 229.87V
20% 18.972A 2.953A 2.944A 1.179A 260 92.291% 1598 26.2 40.62C 0.89
12.076V 5.079V 3.363V 5.087V 281.72 45.32C 229.86V
30% 29.309A 3.45A 3.444A 1.376A 389.764 93.43% 1647 27.4 41.28C 0.973
12.068V 5.072V 3.354V 5.086V 417.178 46.36C 229.85V
40% 39.678A 3.95A 3.947A 1.574A 519.743 93.823% 1733 28.8 41.56C 0.979
12.061V 5.064V 3.345V 5.082V 553.964 47.05C 229.83V
50% 49.731A 4.949A 4.951A 1.773A 649.887 93.858% 1815 30.2 42.02C 0.984
12.052V 5.053V 3.333V 5.076V 692.441 48.05C 229.81V
60% 59.799A 5.951A 5.961A 1.973A 780.022 93.713% 1939 32.4 42.59C 0.986
12.044V 5.042V 3.322V 5.068V 832.357 49.29C 229.8V
70% 69.873A 6.96A 6.98A 2.174A 910.024 93.485% 1951 32.7 42.94C 0.988
12.035V 5.03V 3.31V 5.06V 973.463 50.03C 229.78V
80% 79.965A 7.975A 8.005A 2.276A 1039.601 93.155% 2006 33.3 43.49C 0.989
12.026V 5.018V 3.298V 5.053V 1115.968 51.52C 229.77V
90% 90.479A 8.486A 8.516A 2.379A 1169.813 92.722% 2487 39.3 44.79C 0.984
12.017V 5.009V 3.288V 5.045V 1261.623 54.02C 229.75V
100% 100.764A 9.005A 9.064A 2.986A 1299.528 91.993% 3300 47.2 45.20C 0.986
12.006V 4.999V 3.277V 5.024V 1412.65 55.29C 229.73V
110% 111.006A 10.032A 10.204A 2.99A 1429.78 91.391% 3270 47.0 46.78C 0.987
11.994V 4.986V 3.263V 5.018V 1564.491 57.71C 229.72V
CL1 0.116A 14.393A 14.337A 0A 121.306 83.993% 1678 28.0 37.67C 0.821
12.076V 5.017V 3.326V 5.035V 144.418 43.26C 229.87V
CL2 0.116A 20.011A 0A 0A 101.422 82.34% 1609 26.4 37.72C 0.795
12.083V 4.999V 3.377V 5.04V 123.18 45.01C 229.87V
CL3 0.116A 0A 19.897A 0A 67.386 76.351% 1648 27.4 39.92C 0.729
12.079V 5.096V 3.316V 5.035V 88.259 49.08C 229.88V
CL4 108.187A 0.001A 0A 0A 1299.982 92.648% 2546 40.0 46.12C 0.986
12.016V 5.055V 3.316V 4.995V 1403.141 57.02C 229.74V

Ripple Suppression

Test 12V 5V 3.3V 5VSB Pass/Fail
10% Load 11.5 mV 6.3 mV 8.3 mV 9.7 mV Pass
20% Load 18.1 mV 7.7 mV 9.1 mV 12.1 mV Pass
30% Load 23.7 mV 8.7 mV 11.2 mV 15.2 mV Pass
40% Load 28.6 mV 10.4 mV 11.3 mV 16.7 mV Pass
50% Load 34.9 mV 12.0 mV 12.7 mV 23.6 mV Pass
60% Load 40.8 mV 14.7 mV 14.3 mV 21.1 mV Pass
70% Load 44.6 mV 16.1 mV 16.5 mV 19.1 mV Pass
80% Load 45.9 mV 19.1 mV 18.9 mV 21.0 mV Pass
90% Load 50.4 mV 23.6 mV 20.3 mV 20.6 mV Pass
100% Load 82.7 mV 26.3 mV 20.9 mV 21.0 mV Pass
110% Load 94.5 mV 31.6 mV 17.7 mV 20.3 mV Pass
Crossload 1 18.8 mV 13.3 mV 16.5 mV 6.8 mV Pass
Crossload 2 10.2 mV 8.9 mV 15.2 mV 5.1 mV Pass
Crossload 3 9.1 mV 10.7 mV 10.5 mV 5.8 mV Pass
Crossload 4 81.6 mV 20.1 mV 12.8 mV 9.4 mV Pass

Ripple is high in the full load and overload tests, but I cannot be extra picky here since we are talking about a 1300W SFX unit!