1st Player NGDP 750W PSU Review

Load Regulation

Test 12V 5V 3.3V 5VSB DC/AC (Watts) Efficiency Fan Speed (RPM) PSU Noise (dB[A]) Temps (In/Out) PF/AC Volts
10% 4.484A 1.979A 1.987A 0.985A 75.009 85.409% 924 21.1 40.26C 0.982
11.908V 5.055V 3.322V 5.08V 87.823 44.48C 115.16V
20% 10.004A 2.97A 2.983A 1.186A 149.981 89.29% 978 23.0 40.70C 0.988
11.902V 5.052V 3.319V 5.061V 167.969 45.27C 115.14V
30% 15.881A 3.467A 3.484A 1.389A 224.99 90.49% 1012 24.0 41.27C 0.993
11.897V 5.049V 3.316V 5.043V 248.648 46.28C 115.12V
40% 21.769A 3.964A 3.985A 1.593A 300.083 90.709% 1059 25.7 41.68C 0.995
11.892V 5.047V 3.313V 5.024V 330.82 47.24C 115.1V
50% 27.273A 4.958A 4.986A 1.799A 374.7 90.514% 1134 27.7 42.14C 0.996
11.887V 5.044V 3.31V 5.005V 413.97 48.21C 115.08V
60% 32.808A 5.953A 5.99A 2.001A 449.586 90.106% 1217 29.9 42.79C 0.997
11.882V 5.041V 3.306V 4.986V 498.952 49.32C 115.06V
70% 38.348A 6.95A 6.996A 2.216A 524.542 89.504% 1447 34.8 43.25C 0.997
11.876V 5.038V 3.302V 4.965V 586.052 50.31C 115.05V
80% 43.961A 7.947A 8.003A 2.323A 599.749 88.862% 1532 36.4 43.89C 0.997
11.870V 5.034V 3.299V 4.951V 674.921 51.99C 115.01V
90% 49.919A 8.449A 8.496A 2.431A 674.791 88.098% 1624 38.0 44.47C 0.998
11.865V 5.031V 3.295V 4.936V 765.961 53.51C 115V
100% 55.678A 8.95A 9.02A 3.066A 749.999 87.283% 1750 39.7 45.66C 0.998
11.859V 5.028V 3.293V 4.894V 859.281 55.67C 114.98V
110% 61.313A 9.951A 10.126A 3.072A 825.044 86.336% 1847 41.0 46.76C 0.998
11.853V 5.025V 3.288V 4.884V 955.625 57.69C 114.96V
CL1 0.118A 14.35A 14.429A 0A 121.303 82.967% 1526 36.2 40.35C 0.986
11.903V 5.031V 3.306V 5.108V 146.206 45.84C 115.14V
CL2 0.118A 19.9A 0A 0A 101.4 82.096% 1237 30.3 40.61C 0.982
11.908V 5.025V 3.324V 5.121V 123.514 47.71C 115.15V
CL3 0.117A 0A 19.987A 0A 67.391 76.468% 1437 34.4 40.22C 0.982
11.905V 5.057V 3.302V 5.116V 88.129 49.31C 115.16V
CL4 63.202A 0A 0A 0A 749.719 88.133% 1534 36.4 45.79C 0.998
11.862V 5.047V 3.305V 5.072V 850.669 56.74C 114.98V

Load regulation is tight at 12V and tight enough at 5V. It should be within 1% at 3.3V, while the 5VSB rail has loose load regulation, but it doesn’t really matter on this rail from the moment it is above the limit that the ATX spec sets.

Ripple Suppression

Test 12V 5V 3.3V 5VSB Pass/Fail
10% Load 13.3 mV 7.7 mV 7.2 mV 7.4 mV Pass
20% Load 13.6 mV 7.6 mV 7.5 mV 7.8 mV Pass
30% Load 13.1 mV 6.8 mV 7.3 mV 7.6 mV Pass
40% Load 14.1 mV 8.3 mV 7.9 mV 8.5 mV Pass
50% Load 14.4 mV 8.8 mV 8.7 mV 9.4 mV Pass
60% Load 14.6 mV 10.6 mV 9.0 mV 9.4 mV Pass
70% Load 14.8 mV 10.0 mV 8.9 mV 9.8 mV Pass
80% Load 15.8 mV 10.0 mV 12.0 mV 10.5 mV Pass
90% Load 15.1 mV 9.6 mV 10.9 mV 10.0 mV Pass
100% Load 27.7 mV 12.4 mV 14.9 mV 15.0 mV Pass
110% Load 28.3 mV 11.8 mV 13.8 mV 15.4 mV Pass
Crossload 1 19.3 mV 12.2 mV 14.4 mV 22.6 mV Pass
Crossload 2 13.2 mV 8.3 mV 8.6 mV 19.2 mV Pass
Crossload 3 12.6 mV 9.6 mV 12.0 mV 18.5 mV Pass
Crossload 4 27.4 mV 8.5 mV 7.9 mV 24.9 mV Pass

Ripple suppression is good on all rails.