Test Methodology
I use an LW-9266 Fan PQ performance measurement apparatus to evaluate cooling fans. This is a highly sophisticated scientific instrument made in Taiwan by Long Win.
Fan Testing Machine Technical Specifications:
- Manufacturer: Long Win Science & Technology Corporation
- Air Flow Rate: 2.4 – 250 CFM
- Accuracy of Air Flow Rage: <3.5% INFS
- Repeatability error: < 2%
- Static pressure: 0-20mmAq (100mmAq with the high static pressure throttle device)
- Overall Dimensions: 0.7 (W) x 2.2 (L) x 1.6 (H) m
- Power Source: 220VAC, 5A, Single Phase, 50/60Hz
- Based on Standards: ISO 5801-2007, AMCA 210-0, ASHRAE 51-2007, IEC 61591-2005, GB/T 1236-200
Besides the Long Win machine, I also use the following equipment.
Testing Equipment:
- Noise Test Environment: Hemi-Anechoic Chamber with 6 dB(A) noise floor
- Conditions: 25 (+-2) degrees Celsius, 40-50% humidity
- Sound Analyzer: Bruel & Kjaer 2270-S G4
- Microphone: Bruel & Kjaer Type 4955-A
- Mic Calibrator: Bruel & Kjaer Type 4231
- Data Logger: Picoscope TC-08
Pages:
Just wondering if the power consumption figures also include led lighting? Even without lighting consumption figures are impressive, just wondering how much additional power those leds suck.
Nope, it doesn’t include LED lighting.