Thermaltake Toughpower GF3 ARGB 750W PSU Review

Protection Features

OCP (Cold @ 27°C) 12V: 90A (144%), 12.004V
5V: 25.6A (128%), 4.993V
3.3V: 25.8A (129%), 3.301V
5VSB: 5.4A (180%), 4.966V
OCP (Hot @ 47°C) 12V: 89.4A (143.04%), 12.014V
5V: 25.6A (128%), 4.988V
3.3V: 24.7A (123.5%), 3.291V
5VSB: 5.4A (180%), 4.969V
OPP (Cold @ 27°C) 1020.25W (136.03%)
OPP (Hot @ 45°C) 922.16W (122.95%)
OTP ✓ (106°C @ secondary side)
SCP 12V to Earth: ✓
5V to Earth: ✓
3.3V to Earth: ✓
5VSB to Earth: ✓
-12V to Earth: ✓
PWR_OK Proper operation
NLO
SIP Surge: MOV
Inrush: NTC Thermistor & Bypass relay

The over current protection is set high at 12V, even under hot conditions. OCP is set within 130% on the minor rails, so everything is fine there. Over temperature, protection is set lower than expected, but I didn’t encounter any problems during testing, so you likely won’t either. Lastly, over power protection is set correctly, especially at high temperatures where it drops notably below 130%.