Protection Features
OCP (Cold @ 27°C) | 12V: 127.6A (127.6%), 11.888V 5V: 28.3A (141.5%), 4.994V 3.3V: 29.5A (147.5%), 3.351V 5VSB: 5A (166.67%), 5.017V |
OCP (Hot @ 40°C) | 12V: 125.2A (125.2%), 11.895V 5V: 28.4A (142%), 5.013V 3.3V: 29.6A (148%), 3.341V 5VSB: 4.7A (156.67%), 5.028V |
OPP (Cold @ 28°C) | 1463.10W (121.92%) |
OPP (Hot @ 41°C) | 1415.57W (117.96%) |
OTP | ✓ (127°C @ 12V Heat Sink) |
SCP | 12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓ |
PWR_OK | Proper operation |
NLO | ✓ |
Fan Failure Protection | ✗ |
SIP | Surge: MOV Inrush: NTC Thermistor & Bypass relay |
Given the unit’s high capacity, OCP at 12V and OPP are reasonably set. On the other hand, the minor rails have highly set OCP triggering points. The rest of the essential protection features are present and operate correctly.