Thermaltake Toughpower GF A3 1200W PSU Review

Protection Features

OCP (Cold @ 27°C) 12V: 127.6A (127.6%), 11.888V
5V: 28.3A (141.5%), 4.994V
3.3V: 29.5A (147.5%), 3.351V
5VSB: 5A (166.67%), 5.017V
OCP (Hot @ 40°C) 12V: 125.2A (125.2%), 11.895V
5V: 28.4A (142%), 5.013V
3.3V: 29.6A (148%), 3.341V
5VSB: 4.7A (156.67%), 5.028V
OPP (Cold @ 28°C) 1463.10W (121.92%)
OPP (Hot @ 41°C) 1415.57W (117.96%)
OTP ✓ (127°C @ 12V Heat Sink)
SCP 12V to Earth: ✓
5V to Earth: ✓
3.3V to Earth: ✓
5VSB to Earth: ✓
-12V to Earth: ✓
PWR_OK Proper operation
NLO
Fan Failure Protection
SIP Surge: MOV
Inrush: NTC Thermistor & Bypass relay

Given the unit’s high capacity, OCP at 12V and OPP are reasonably set. On the other hand, the minor rails have highly set OCP triggering points. The rest of the essential protection features are present and operate correctly.