Protection Features

OCP (Cold @ 25°C)

12V: 119.8A (119.8%), 11.952V
5V: 30.5A (138.64%), 5.045V
3.3V: 30.5A (138.64%), 3.291V
5VSB: 5.3A (176.67%), 4.945V

OCP (Hot @ 41°C)

12V: 120A (120%), 11.972V
5V: 30.4A (138.18%), 5.052V
3.3V: 30.5A (138.64%), 3.291V
5VSB: 5.3A (176.67%), 4.944V

OPP (Cold @ 28°C)

1427.28W (118.94%)

OPP (Hot @ 43°C)

1427.26W (118.94%)

OTP

✓ (129°C @ 12V Heat Sink)

SCP

12V to Earth: ✓
5V to Earth: ✓
3.3V to Earth: ✓
5VSB to Earth: ✓
-12V to Earth: ✓

PWR_OK

Proper operation

NLO

SIP

Surge: MOV
Inrush: NTC Thermistor & Bypass relay

The OCP triggering point at 12V and the OPP are correctly set. On the other hand, the minor rails have high OCP points without any reason. The other protection features are present and operate well.