Transient Response
20% Load – 20ms
Voltage | Before | After | Change | Pass/Fail |
12V | 12.112V | 11.917V | 1.61% | Pass |
5V | 5.037V | 4.961V | 1.52% | Pass |
3.3V | 3.293V | 3.192V | 3.07% | Pass |
5VSB | 5.021V | 4.953V | 1.36% | Pass |
50% Load -20ms
Voltage | Before | After | Change | Pass/Fail |
12V | 12.043V | 11.960V | 0.68% | Pass |
5V | 5.027V | 4.961V | 1.32% | Pass |
3.3V | 3.289V | 3.186V | 3.13% | Pass |
5VSB | 5.005V | 4.939V | 1.32% | Pass |
The transient response deviations are low on all rails but 12V, which I would like to see below the 1% average.
Transient Response ATX v3.0 Tests
The PSU successfully passed all ATX v3.0 transient response tests.
The 12V rail drops low during the 200% load test.