Protection Features

OCP (Cold @ 27°C) 12V: 85.2A (136.32%), 11.888V
5V: 32.3A (161.5%), 5.001V
3.3V: 32A (160%), 3.284V
5VSB: 3.9A (130%), 4.937V
OCP (Hot @ 44°C) 12V: 83.2A (133.12%), 11.888V
5V: 31.8A (159%), 5.001V
3.3V: 31.4A (157%), 3.285V
5VSB: 3.9A (130%), 4.93V
OPP (Cold @ 27°C) 1093.98W (145.86%)
OPP (Hot @ 43°C) 1029.92W (137.32%)
OTP ✓ (155°C @ +12V heat sink)
SCP 12V to Earth: ✓
5V to Earth: ✓
3.3V to Earth: ✓
5VSB to Earth: ✓
-12V to Earth: ✓
PWR_OK Proper operation
NLO
Fan Failure Protection
SIP Surge: MOV
Inrush: NTC Thermistor & Bypass relay

OCP is properly set at 12V, given the PSU’s mid-capacity. Unfortunately, this is not the case on the minor rails, where the OCP triggering points are sky-high, and the differences between cold and hot conditions are small. To effectively protect the PSU, OCP triggering points should be notably lower under harsh (e.g., hot) conditions.

The overpower protection is a bit higher than I would like to see (135-140%), but we didn’t encounter any problems during testing.