Protection Features
OCP (Cold @ 27°C) | 12V: 85.2A (136.32%), 11.888V 5V: 32.3A (161.5%), 5.001V 3.3V: 32A (160%), 3.284V 5VSB: 3.9A (130%), 4.937V |
OCP (Hot @ 44°C) | 12V: 83.2A (133.12%), 11.888V 5V: 31.8A (159%), 5.001V 3.3V: 31.4A (157%), 3.285V 5VSB: 3.9A (130%), 4.93V |
OPP (Cold @ 27°C) | 1093.98W (145.86%) |
OPP (Hot @ 43°C) | 1029.92W (137.32%) |
OTP | ✓ (155°C @ +12V heat sink) |
SCP | 12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓ |
PWR_OK | Proper operation |
NLO | ✓ |
Fan Failure Protection | ✗ |
SIP | Surge: MOV Inrush: NTC Thermistor & Bypass relay |
OCP is properly set at 12V, given the PSU’s mid-capacity. Unfortunately, this is not the case on the minor rails, where the OCP triggering points are sky-high, and the differences between cold and hot conditions are small. To effectively protect the PSU, OCP triggering points should be notably lower under harsh (e.g., hot) conditions.
The overpower protection is a bit higher than I would like to see (135-140%), but we didn’t encounter any problems during testing.