Transient Response
20% Load – 20ms
Voltage | Before | After | Change | Pass/Fail |
12V | 11.906V | 11.684V | 1.86% | Pass |
5V | 5.052V | 4.903V | 2.94% | Pass |
3.3V | 3.318V | 3.174V | 4.33% | Pass |
5VSB | 5.061V | 5.006V | 1.08% | Pass |
50% Load -20ms
Voltage | Before | After | Change | Pass/Fail |
12V | 11.891V | 11.760V | 1.10% | Pass |
5V | 5.043V | 4.899V | 2.86% | Pass |
3.3V | 3.307V | 3.158V | 4.51% | Pass |
5VSB | 5.008V | 4.963V | 0.90% | Pass |
The transient response needs improvement on all rails, especially at 3.3V, which drops below 3.2V at both tests.
Transient Response ATX v3.1 Tests
The PSU passes all ATX v3.1 transient response tests.
I would like to see a higher voltage level on the 12V rail in the 200% transient response tests.
Pages:
Does it feature two 12v-2×6 slots but only one cable?