Protection Features
OCP (Cold @ 25°C) | 12V: 91.8A (130.21%), 12.088V 5V: 27.2A (136%), 4.979V 3.3V: 29.1A (145.5%), 3.25V 5VSB: 3.7A (148%), 5.015V |
OCP (Hot @ 40°C) | 12V: 89.4A (126.81%), 12.111V 5V: 26.2A (131%), 4.984V 3.3V: 29A (145.5%), 3.251V 5VSB: 3.7A (148%), 5.012V |
OPP (Cold @ 26°C) | 1083.16W (127.43%) |
OPP (Hot @ 37°C) | 1044.08W (122.83%) |
OTP | ✓ (155°C @ 12V Heat Sink) |
SCP | 12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓ |
PWR_OK | Proper operation |
NLO | ✓ |
Fan Failure Protection | ✗ |
SIP | Surge: MOV Inrush: NTC Thermistor & Bypass relay |
OCP at 12V and OPP are correctly set, not allowing the PSU to exceed its limits. I will also give a pass to the 5V rail’s OCP setting, but I cannot do that at 3.3V since there is no reason for this rail to go so high! All other essential protection features are present and work well.