Protection Features

OCP (Normal @ 29.2°C) 12V: 102.00A (122.89%), 12.078V
5V: 27.1A (135.50%), 5.045V
3.3V: 27A (135.00%), 3.285V
5VSB: 3.8A (126.67%), 5.067V
OCP (Hot @ 44.5°C) 12V: 98.60A (118.80%), 12.094V
5V: 26.5A (132.50%), 5.045V
3.3V: 26A (130.00%), 3.288V
5VSB: 3.8A (126.67%), 5.064V
OPP (Normal @ 30.7°C) 1281.07W (128.11%)
OPP (Hot @ 44.8°C) 1263.08W (126.31%)
OTP ✓ (105°C @ Heat Sink)
SCP 12V to Earth: ✓
5V to Earth: ✓
3.3V to Earth: ✓
5VSB to Earth: ✓
-12V to Earth: ✓
PWR_OK Proper Operation
NLO
Fan Failure Protection
SIP Surge: MOV
Inrush: NTC & Bypass Relay

The 12V rail’s OCP triggering points are conservatively set. The minor rails have OCP triggering points close to 135% at normal conditions, which drop at high temperatures to protect the PSU.

The Over Power Protection is set below 130% at normal temperatures. It should be set lower, though, at high temperatures since currently, the difference between normal and high temperatures is only 2%.