Transient Response
20% Load – 20ms
Advanced Transient Response 20% - 50 Hz - No Caps | ||||
Voltage | Before | After | Change | Pass/Fail |
12V | 12.084V | 11.858V | 1.86% | Pass |
5V | 5.079V | 4.976V | 2.03% | Pass |
3.3V | 3.320V | 3.180V | 4.20% | Pass |
5VSB | 5.107V | 5.068V | 0.76% | Pass |
50% Load -20ms
Advanced Transient Response 50% - 50 Hz - No Caps | ||||
Voltage | Before | After | Change | Pass/Fail |
12V | 12.073V | 11.945V | 1.06% | Pass |
5V | 5.069V | 4.957V | 2.21% | Pass |
3.3V | 3.308V | 3.174V | 4.04% | Pass |
5VSB | 5.071V | 5.001V | 1.37% | Pass |
The transient response without capacitors helping the PSU is mediocre on all rails.
Transient Response ATX v3.1 Tests
The PSU passes all ATX v3.1 transient response tests, but the 12V and 3.3V rails drop low.
The 12V rail’s performance isn’t that good in these tests compared to similar spec PSUs.
Pages:
hello Aris based on your tier list which is better Unicon or Toshin Kogyo caps or it’s just on a same level ?
I haven’t tested any Unicon caps so far, electrolytic ones. TKs, the one I tested are pretty good!
so between TK LGW/LGWA/LGWB with TK LW/LFW/LFWB/LCW what’s different, i look at TK website there are no TK LW/LFW/LFWB/LCW on that product list but i’ve seen some cheap power supply with japan capacitor gimmick use these caps, so do they had real lifetime performance similar to LGW/LGWA/LGWB product or similar to other chinese caps like LTEC or ChengX ?
Not a clue, I just test whatever falls into my hands now. I will deal with details once I post the full database.
Hi, I was wondering if you could answer some questions that I have concerns about. I recently purchased this psu Lian Li Edge 1000w gold and installed it in my rig to power an rtx 5080.
With all these issues of 12vhpwr cables melting, I decided to check my 12v core voltages on hwinfo and noticed that this psu is showing readings of about 11.8v for PCIe and 16-pin, and would dip to as low as 11.6v under load.
I’ve tried checking all the cables and made sure they’re seated properly to avail.
Am I being too paranoid or do these reading look abnormally low. Should I submit and RMA and return the product?