Hold Up Time
The hold-up time doesn’t exceed 17ms, and the power ok signal’s hold-up time is lower than 16ms. This would be a problem if the PSU claimed ATX v3.0 compatibility but not an issue for the ATX v3.1 spec, which is looser in this section.
Inrush Current
The inrush currents are at normal levels.
Timings
The PSU supports Alternative Low Power Modes. The T1 period is extremely low!