Protection Features

OCP (Cold @ 26°C) 12V: 75.4A (139.63%), 11.923V
5V: 29.6A (148%), 4.965V
3.3V: 29.7A (148.5%), 3.269V
5VSB: 4.3A (143.33%), 5.014V
OCP (Hot @ 39°C) 12V: 71.8A (132.96%), 11.94V
5V: 28.8A (144%), 4.967V
3.3V: 29.5A (147.5%), 3.269V
5VSB: 4.4A (146.67%), 5.003V
OPP (Cold @ 29°C) 891.13W (137.10%)
OPP (Hot @ 37°C) 841.20W (129.42%)
OTP ✓ (110°C @ 12V Heat Sink)
SCP 12V to Earth: ✓
5V to Earth: ✓
3.3V to Earth: ✓
5VSB to Earth: ✓
-12V to Earth: ✓
PWR_OK Accurate but lower than 16ms
NLO
Fan Failure Protection
SIP Surge: MOV
Inrush: NTC Thermistor & Bypass relay

OCP is set high at 12V and extra-high on the minor rails, which should be close to 130%. There is no need for close to 30A at 3.3V. OPP is also pretty highly set, with the PSU operating at normal temperatures, but it drops close to 130% at high temperatures. Lastly, all other necessary protection features are present.