XPG Core Reactor II VE 750W PSU Review

Load Regulation

Test 12V 5V 3.3V 5VSB DC/AC (Watts) Efficiency Fan Speed (RPM) PSU Noise (dB[A]) Temps (In/Out) PF/AC Volts
10% 4.377A 1.97A 1.999A 0.99A 75.009 85.695% 942 22.2 40.31C 0.971
12.201V 5.077V 3.302V 5.053V 87.532 44.32C 115.16V
20% 9.834A 2.957A 3.002A 1.189A 149.975 89.938% 944 22.3 40.51C 0.99
12.108V 5.074V 3.299V 5.047V 166.754 44.81C 115.14V
30% 15.621A 3.451A 3.505A 1.389A 224.986 90.891% 946 22.4 41.22C 0.993
12.094V 5.072V 3.296V 5.039V 247.532 45.95C 115.12V
40% 21.420A 3.946A 4.009A 1.591A 300.079 90.874% 949 22.5 41.65C 0.991
12.086V 5.07V 3.293V 5.031V 330.212 46.67C 115.09V
50% 26.721A 4.936A 5.016A 1.792A 374.733 90.481% 954 22.6 42.39C 0.991
12.134V 5.066V 3.29V 5.024V 414.157 47.87C 115.07V
60% 32.140A 5.928A 6.026A 1.994A 449.647 89.588% 1428 35.9 42.95C 0.992
12.129V 5.062V 3.286V 5.016V 501.903 49.09C 115.05V
70% 37.583A 6.923A 7.04A 2.197A 524.566 88.832% 1753 40.9 43.12C 0.993
12.118V 5.057V 3.282V 5.008V 590.512 50.19C 115.03V
80% 43.104A 7.917A 8.055A 2.299A 599.776 88.118% 2007 44.4 43.62C 0.994
12.107V 5.053V 3.278V 5.003V 680.648 51.71C 115V
90% 48.960A 8.417A 8.551A 2.402A 674.822 87.407% 2289 48.8 44.77C 0.995
12.098V 5.05V 3.274V 4.997V 772.053 53.88C 114.98V
100% 54.615A 8.917A 9.078A 3.016A 750.041 86.566% 2414 49.5 45.50C 0.995
12.091V 5.047V 3.272V 4.975V 866.445 55.52C 114.95V
110% 60.138A 9.914A 10.189A 3.016A 825.081 85.634% 2413 49.5 46.59C 0.996
12.085V 5.044V 3.268V 4.974V 963.498 57.51C 114.93V
CL1 0.116A 14.289A 14.502A 0A 121.309 83.582% 970 23.2 41.14C 0.987
12.134V 5.053V 3.289V 5.111V 145.138 46.59C 115.15V
CL2 0.115A 21.744A 0A 0A 111.402 81.781% 972 23.3 41.48C 0.984
12.147V 5.059V 3.31V 5.152V 136.222 48.52C 115.14V
CL3 0.115A 0A 22.052A 0A 73.996 76.888% 949 22.5 41.00C 0.978
12.148V 5.08V 3.292V 5.075V 96.239 50.06C 115.15V
CL4 62.033A 0.001A 0.004A 0.001A 749.843 87.421% 2411 49.4 45.61C 0.995
12.088V 5.071V 3.287V 5.06V 857.741 56.57C 114.95V

Load regulation is loose at 12V, the most important rail. It is tight at 5V and close to 1% at 3.3V.

Ripple Suppression

Test 12V 5V 3.3V 5VSB Pass/Fail
10% Load 7.0 mV 5.7 mV 5.3 mV 5.2 mV Pass
20% Load 14.0 mV 6.2 mV 7.2 mV 5.4 mV Pass
30% Load 12.6 mV 7.2 mV 9.8 mV 6.5 mV Pass
40% Load 13.4 mV 8.3 mV 12.4 mV 6.9 mV Pass
50% Load 16.0 mV 9.5 mV 14.9 mV 7.9 mV Pass
60% Load 18.3 mV 10.4 mV 17.6 mV 8.9 mV Pass
70% Load 20.8 mV 12.6 mV 20.4 mV 10.1 mV Pass
80% Load 23.0 mV 13.8 mV 25.4 mV 10.8 mV Pass
90% Load 25.1 mV 16.0 mV 28.3 mV 12.9 mV Pass
100% Load 33.3 mV 18.2 mV 31.5 mV 14.2 mV Pass
110% Load 35.5 mV 18.9 mV 35.0 mV 16.0 mV Pass
Crossload 1 27.1 mV 8.3 mV 12.5 mV 6.7 mV Pass
Crossload 2 16.2 mV 11.4 mV 6.8 mV 8.2 mV Pass
Crossload 3 7.8 mV 5.8 mV 13.2 mV 5.4 mV Pass
Crossload 4 32.4 mV 15.7 mV 27.4 mV 12.8 mV Pass

Ripple suppression is decent on all rails but 3.3V, where it should be below 30mV.

Pages ( 4 of 11 ): « Previous123 4 567891011Next »

Related Posts

4 thoughts on “XPG Core Reactor II VE 750W PSU Review

  1. If this were to be evaluated on a tier list, would it be tier A or tier B? And the 850w model is available in my country for 150 dollars, do you think it is worth buying?

    1. I don’t do tiers, I do best PSUs with actual ratings 🙂 Please check the corresponding article
      I think it is expensive at 150 dollars, always for amazon.com standards/

  2. i think ELITE the best tier 2 caps on a market, i found out ASUS PRIME PSU was using non Japanese Caps but used ELITE caps as a bulk Caps

Leave a Reply