XPG Core Reactor II VE 650W PSU Review

Protection Features

OCP (Cold @ 28°C) 12V: 67A (123.84%), 12.043V
5V: 29.6A (148%), 5.036V
3.3V: >28A (>140%), <3.136V
5VSB: 5A (166.67%), 4.895V
OCP (Hot @ 43°C) 12V: 66.4A (122.74%), 12.077V
5V: 28.2A (141%), 5.049V
3.3V: 30.5A (152.5%), 3.136V
5VSB: 5A (166.67%), 4.884V
OPP (Cold @ 28°C) 794.83W (122.28%)
OPP (Hot @ 43°C) 794.8W (122.28%)
OTP ✓ (120°C @ secondary side)
SCP 12V to Earth: ✓
5V to Earth: ✓
3.3V to Earth: ✓
5VSB to Earth: ✓
-12V to Earth: ✓
PWR_OK Proper operation
NLO
Fan Failure Protection
SIP Surge: MOV
Inrush: NTC Thermistor

OCP is set below 130% at 12V, but its triggering points are close in cold and hot conditions, which is incorrect. OCP is highly set at 3.3V, especially at high temperatures. This is a fine way to destroy the PSU! The same goes for the 5V rail, but at least at high temperatures, OCP’s triggering point drops notably.

The over power protection is conservatively set, but I would like to see a lower trigger point at high temperatures. Lastly, all other essential protection features are present.