Protection Features
OCP (Cold @ 25°C) | 12V: 103.8A (146.61%), 11.894V 5V: 27.1A (135.5%), 4.961V 3.3V: 26.6A (133%), 3.289V 5VSB: 5.3A (176.67%), 4.976V |
OCP (Hot @ 45°C) | 12V: 101.2A (142.94%), 11.906V 5V: 26.1A (130.5%), 4.951V 3.3V: 26A (130%), 3.284V 5VSB: 5.3A (176.67%), 4.978V |
OPP (Cold @ 27°C) | 1232.83W (145.04%) |
OPP (Hot @ 43°C) | 1167.89W (137.40%) |
OTP | ✓ (110°C @ secondary side) |
SCP | 12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓ |
PWR_OK | Proper operation |
NLO | ✓ |
SIP | Surge: MOV Inrush: NTC Thermistor & Bypass relay |
The over current protection is set high at 12V, even under hot conditions. OCP is within 130-140% on the minor rails, so I won’t complain. Over temperature, protection is set lower than expected, but I didn’t encounter any problems during testing, so you likely won’t either. Lastly, over power protection should be closer to 130% at high temperatures.