Thermalright TR-TGFX 550 ATX v3.1 PSU Review

Load Regulation

Test 12V 5V 3.3V 5VSB DC/AC (Watts) Efficiency Fan Speed (RPM) PSU Noise (dB[A]) Temps (In/Out) PF/AC Volts
10% 2.762A 1.973A 1.963A 0.998A 54.996 84.356% 1421 16.9 40.30°C 0.949
12.093V 5.069V 3.361V 5.012V 65.195 41.47°C 114.83V
20% 6.541A 2.96A 2.946A 1.2A 109.922 88.944% 1426 17 40.78°C 0.967
12.081V 5.067V 3.36V 5.001V 123.586 42.17°C 114.81V
30% 10.676A 3.454A 3.439A 1.403A 164.913 90.507% 1451 17.5 41.08°C 0.967
12.070V 5.066V 3.359V 4.99V 182.209 42.96°C 114.8V
40% 14.821A 3.949A 3.931A 1.607A 219.989 91.114% 1695 22.5 41.64°C 0.972
12.064V 5.065V 3.358V 4.979V 241.444 43.89°C 114.77V
50% 18.619A 4.938A 4.916A 1.812A 274.983 91.047% 2308 32.1 42.43°C 0.978
12.057V 5.063V 3.356V 4.967V 302.02 44.66°C 114.76V
60% 22.421A 5.928A 5.903A 2A 329.881 90.76% 2729 36.5 42.92°C 0.981
12.050V 5.061V 3.354V 4.956V 363.466 45.03°C 114.74V
70% 26.218A 6.918A 6.891A 2.225A 384.965 89.654% 3103 40.6 43.14°C 0.984
12.047V 5.059V 3.353V 4.944V 429.392 45.38°C 114.72V
80% 30.019A 7.908A 7.877A 2.331A 439.384 89.313% 3103 40.6 43.89°C 0.986
12.042V 5.057V 3.351V 4.934V 491.957 47.62°C 114.71V
90% 34.212A 8.404A 8.357A 2.437A 494.41 88.894% 3104 40.6 44.84°C 0.987
12.040V 5.057V 3.35V 4.925V 556.184 49.03°C 114.69V
100% 38.208A 8.9A 8.867A 3.061A 549.622 88.259% 3104 40.6 45.45°C 0.988
12.037V 5.056V 3.349V 4.901V 622.744 50.41°C 114.65V
110% 42.071A 9.893A 9.947A 3.065A 604.628 87.558% 3104 40.6 46.60°C 0.989
12.035V 5.054V 3.347V 4.894V 690.551 52.89°C 114.64V
CL1 0.114A 11.91A 11.855A 0A 101.282 83.626% 2908 38.7 42.94°C 0.968
12.086V 5.054V 3.349V 5.026V 121.112 45.99°C 114.81V
CL2 0.114A 19.782A 0A 0A 101.317 83.011% 2337 32.2 41.24°C 0.968
12.086V 5.052V 3.357V 5.029V 122.053 43.68°C 114.8V
CL3 0.114A 0A 19.718A 0A 67.379 78.943% 1775 23.8 41.00°C 0.957
12.090V 5.065V 3.347V 5.029V 85.354 42.93°C 114.82V
CL4 45.633A 0A 0A 0.001A 549.513 89.309% 3116 40.7 44.48°C 0.988
12.042V 5.069V 3.361V 4.993V 615.296 48.23°C 114.65V

Load regulation is tight. The PSU’s low capacity helps in that.

Ripple Suppression

Test 12V 5V 3.3V 5VSB Pass/Fail
10% Load 26.7 mV 18.9 mV 16.6 mV 11.6 mV Pass
20% Load 40.4 mV 20.1 mV 18.2 mV 13.7 mV Pass
30% Load 50.5 mV 20.5 mV 17.3 mV 15.3 mV Pass
40% Load 44.5 mV 21.3 mV 18.3 mV 17.0 mV Pass
50% Load 39.4 mV 22.2 mV 17.9 mV 19.8 mV Pass
60% Load 38.7 mV 25.2 mV 19.2 mV 21.0 mV Pass
70% Load 46.8 mV 27.4 mV 19.6 mV 26.6 mV Pass
80% Load 49.5 mV 29.8 mV 22.4 mV 28.4 mV Pass
90% Load 48.1 mV 33.2 mV 22.3 mV 29.7 mV Pass
100% Load 76.0 mV 36.0 mV 23.3 mV 38.0 mV Pass
110% Load 76.2 mV 38.4 mV 24.7 mV 40.5 mV Pass
Crossload 1 60.2 mV 22.5 mV 20.1 mV 21.7 mV Pass
Crossload 2 46.1 mV 26.7 mV 15.8 mV 20.8 mV Pass
Crossload 3 38.2 mV 22.5 mV 23.4 mV 19.4 mV Pass
Crossload 4 70.6 mV 34.4 mV 23.3 mV 37.3 mV Pass

Ripple suppression is mediocre, especially at 12V. This is a great shame! With more and higher quality caps on the secondary side, this wouldn’t be an issue, but Thermalright targeted budget-oriented users and an increased number of higher-quality caps would increase the production cost.

Pages ( 4 of 11 ): « Previous123 4 567891011Next »

Related Posts

6 thoughts on “Thermalright TR-TGFX 550 ATX v3.1 PSU Review

  1. Can you do a review of the Thermalright TP-1000/1200? There’s a frustratingly low amount of information about it. Thanks in advance.

Leave a Reply

Your email address will not be published. Required fields are marked *

Please consider turning off your adblocker to support our work! We work night and day to offer quality content, and ads help us continue our work! Thank you! The Hardware Busters Team