Super Flower Leadex VII PRO 1000W ATX v3.1 PSU Review

Load Regulation

Test 12V 5V 3.3V 5VSB DC/AC (Watts) Efficiency Fan Speed (RPM) PSU Noise (dB[A]) Temps (In/Out) PF/AC Volts
10% 6.483A 1.973A 1.963A 0.975A 99.984 88.369% 0 <6.0 44.22C 0.952
12.091V 5.067V 3.362V 5.126V 113.154 40.01C 114.81V
20% 13.983A 2.959A 2.943A 1.173A 199.928 91.639% 0 <6.0 45.40C 0.981
12.089V 5.068V 3.363V 5.116V 218.17 40.88C 114.76V
30% 21.838A 3.451A 3.433A 1.371A 299.969 92.407% 0 <6.0 46.24C 0.99
12.085V 5.071V 3.364V 5.106V 324.608 41.16C 114.74V
40% 29.647A 3.942A 3.922A 1.57A 399.47 92.475% 378 <6.0 41.76C 0.993
12.085V 5.073V 3.366V 5.096V 431.963 47.27C 114.7V
50% 37.132A 4.929A 4.902A 1.769A 499.196 91.981% 622 19.5 42.06C 0.994
12.084V 5.072V 3.366V 5.087V 542.716 48.12C 114.67V
60% 44.680A 5.916A 5.883A 1.97A 599.726 91.33% 890 31.2 42.74C 0.995
12.084V 5.071V 3.366V 5.078V 656.67 49.30C 114.64V
70% 52.166A 6.902A 6.864A 2.17A 699.46 90.718% 1153 38.9 43.25C 0.996
12.083V 5.071V 3.365V 5.068V 771.023 50.29C 114.6V
80% 59.718A 7.888A 7.843A 2.273A 799.479 90.012% 1400 44.9 43.88C 0.996
12.083V 5.07V 3.365V 5.06V 888.187 51.96C 114.57V
90% 67.598A 8.38A 8.317A 2.376A 899.297 89.317% 1615 48.8 44.26C 0.996
12.083V 5.071V 3.366V 5.051V 1006.87 53.35C 114.53V
100% 75.543A 8.872A 8.82A 2.479A 1000.002 88.589% 1806 50.5 45.83C 0.996
12.084V 5.072V 3.367V 5.043V 1128.839 55.83C 114.49V
110% 83.083A 9.855A 9.887A 2.482A 1099.813 87.742% 1994 52.6 46.72C 0.996
12.085V 5.074V 3.368V 5.036V 1253.469 57.63C 114.46V
CL1 0.115A 11.881A 11.81A 0A 101.294 83.234% 710 24.0 40.37C 0.958
12.093V 5.067V 3.361V 5.137V 121.717 48.96C 114.8V
CL2 0.114A 19.702A 0A 0A 101.334 82.662% 617 19.3 40.81C 0.959
12.092V 5.073V 3.365V 5.137V 122.6 49.41C 114.81V
CL3 0.114A 0A 19.621A 0A 67.381 76.977% 790 27.8 40.06C 0.937
12.092V 5.071V 3.364V 5.14V 87.551 45.65C 114.81V
CL4 82.768A 0.001A 0A 0.001A 999.881 89.336% 1608 49.1 45.61C 0.996
12.080V 5.074V 3.371V 5.09V 1119.228 53.43C 114.51V

Load regulation is super tight!

Ripple Suppression

Test 12V 5V 3.3V 5VSB Pass/Fail
10% Load 18.3 mV 15.9 mV 16.0 mV 12.4 mV Pass
20% Load 22.7 mV 16.8 mV 16.8 mV 11.3 mV Pass
30% Load 20.8 mV 18.6 mV 18.0 mV 10.9 mV Pass
40% Load 22.7 mV 18.8 mV 19.4 mV 11.0 mV Pass
50% Load 25.5 mV 20.8 mV 21.0 mV 11.5 mV Pass
60% Load 26.8 mV 22.8 mV 23.0 mV 11.5 mV Pass
70% Load 30.6 mV 23.3 mV 22.8 mV 12.2 mV Pass
80% Load 29.3 mV 26.9 mV 26.4 mV 14.9 mV Pass
90% Load 31.6 mV 25.7 mV 26.5 mV 15.1 mV Pass
100% Load 37.7 mV 29.2 mV 28.7 mV 18.3 mV Pass
110% Load 39.9 mV 30.7 mV 31.0 mV 17.8 mV Pass
Crossload 1 24.8 mV 18.1 mV 20.6 mV 31.5 mV Pass
Crossload 2 22.1 mV 23.7 mV 17.9 mV 21.5 mV Pass
Crossload 3 18.2 mV 16.0 mV 20.5 mV 23.2 mV Pass
Crossload 4 37.0 mV 27.6 mV 26.6 mV 26.6 mV Pass

Ripple suppression could be better, especially on the minor rails.

Pages ( 4 of 11 ): « Previous123 4 567891011Next »

Related Posts

10 thoughts on “Super Flower Leadex VII PRO 1000W ATX v3.1 PSU Review

  1. θα μπορούσατε να μου πείτε από που μπορώ να αγοράσω αυτό το τροφοδοτικό? Προορίζεται για radeon rx 7900xtx και 7800x3d

    1. Δυστυχώς η Super Flower δεν έχει ακόμη distributor στην Ευρώπη. Ρίξε μια ματιά στην Caseking αν το φέρνει.

  2. Hi,

    On page 2 (Box & Bundle, Product Photos & Cables), statement “The modular panel around the back hosts thirteen sockets. Since the PSU doesn’t have a native 12V-2×6 socket, it is automatically ATX v3.1 compliant if it meets the ATX v3.0 requirements.” is confusing to me.

    This statement confuses me because it reads, this PSU is ATX 3.1 compliant since it does not have 12v-2×6 socket.

    1. it means that any PSU that doesn’t have the native 12V-2×6 but uses 2x 8 pin sockets instead AND meets ATX v3.0 spec requirements, automatically meets the ATX v3.1 specs.

      While PSUs with 12VHPWR are NOT since they need the native 12V-2×6. Some brands were smart and used 2x 8 pins (e.g. Corsair, Super Flower) so they didn’t have to make any changes to make their PSUs ATX v3.1 ready.

      1. Hello, could there be an error in the characteristics? What is the correct full-bridge or hall-bridge topology?
        thank you and greetings

Leave a Reply

Your email address will not be published. Required fields are marked *