Transient Response
20% Load – 20ms
Advanced Transient Response 20% - 50 Hz - No Caps | ||||
Voltage | Before | After | Change | Pass/Fail |
12V | 12.191V | 11.992V | 1.63% | Pass |
5V | 5.029V | 4.941V | 1.76% | Pass |
3.3V | 3.319V | 3.161V | 4.75% | Pass |
5VSB | 5.104V | 5.062V | 0.82% | Pass |
50% Load -20ms
Advanced Transient Response 50% - 50 Hz - No Caps | ||||
Voltage | Before | After | Change | Pass/Fail |
12V | 12.178V | 12.096V | 0.67% | Pass |
5V | 5.022V | 4.930V | 1.84% | Pass |
3.3V | 3.309V | 3.141V | 5.07% | Pass |
5VSB | 5.073V | 5.027V | 0.91% | Pass |
The transient response is mediocre at 12V and 3.3V.
Transient Response ATX v3.0 Tests
The PSU passes all ATX v3.0 transient response tests, but the 12V and 3.3V rails drop low in the 200% load test.
The 12V rail performs decently in these tests. Do not forget that in the 200% load test the PSU has to handle a transient load of 2400W.
Pages: