Load Regulation
Test | 12V | 5V | 3.3V | 5VSB | DC/AC (Watts) | Efficiency | Fan Speed (RPM) | PSU Noise (dB[A]) | Temps (In/Out) | PF/AC Volts |
10% | 6.442A | 1.987A | 1.969A | 0.989A | 100 | 84.598% | 0 | <6.0 | 44.38C | 0.961 |
12.169V | 5.035V | 3.352V | 5.056V | 118.208 | 40.15C | 115.11V | ||||
20% | 13.890A | 2.981A | 2.957A | 1.189A | 199.949 | 88.918% | 0 | <6.0 | 45.35C | 0.977 |
12.170V | 5.033V | 3.347V | 5.049V | 224.873 | 40.76C | 115.08V | ||||
30% | 21.685A | 3.479A | 3.455A | 1.389A | 299.994 | 91.091% | 0 | <6.0 | 46.31C | 0.982 |
12.171V | 5.032V | 3.343V | 5.041V | 329.337 | 41.28C | 115.05V | ||||
40% | 29.505A | 3.977A | 3.954A | 1.59A | 399.692 | 91.356% | 0 | <6.0 | 47.12C | 0.985 |
12.150V | 5.031V | 3.339V | 5.033V | 437.511 | 41.54C | 115.02V | ||||
50% | 36.973A | 4.973A | 4.947A | 1.792A | 499.443 | 91.03% | 412 | <6.0 | 42.38C | 0.988 |
12.142V | 5.028V | 3.335V | 5.024V | 548.659 | 48.40C | 115.01V | ||||
60% | 44.523A | 5.971A | 5.943A | 1.994A | 600.015 | 90.527% | 492 | 8.1 | 42.86C | 0.99 |
12.133V | 5.026V | 3.332V | 5.015V | 662.799 | 49.49C | 114.99V | ||||
70% | 52.012A | 6.97A | 6.941A | 2.198A | 699.781 | 89.887% | 700 | 17.4 | 43.14C | 0.992 |
12.125V | 5.023V | 3.328V | 5.006V | 778.517 | 50.25C | 114.97V | ||||
80% | 59.578A | 7.968A | 7.94A | 2.301A | 799.78 | 89.11% | 905 | 25.9 | 43.80C | 0.993 |
12.116V | 5.021V | 3.325V | 4.998V | 897.527 | 51.88C | 114.94V | ||||
90% | 67.472A | 8.469A | 8.428A | 2.405A | 899.545 | 88.26% | 1104 | 31.9 | 44.25C | 0.993 |
12.110V | 5.019V | 3.322V | 4.991V | 1019.192 | 53.31C | 114.9V | ||||
100% | 75.140A | 8.97A | 8.949A | 3.014A | 999.528 | 87.322% | 1368 | 38.9 | 45.68C | 0.993 |
12.109V | 5.017V | 3.318V | 4.977V | 1144.65 | 55.87C | 114.87V | ||||
110% | 82.735A | 9.97A | 10.047A | 3.019A | 1100.136 | 86.309% | 1628 | 43.0 | 46.59C | 0.994 |
12.109V | 5.015V | 3.314V | 4.969V | 1274.641 | 57.47C | 114.83V | ||||
CL1 | 0.115A | 14.364A | 14.35A | 0A | 121.29 | 81.095% | 412 | <6.0 | 40.10C | 0.973 |
12.176V | 5.026V | 3.324V | 5.059V | 149.568 | 52.00C | 115.1V | ||||
CL2 | 0.115A | 21.874A | 0A | 0A | 111.383 | 78.9% | 411 | <6.0 | 40.92C | 0.97 |
12.180V | 5.028V | 3.334V | 5.065V | 141.173 | 51.42C | 115.1V | ||||
CL3 | 0.114A | 0A | 21.943A | 0A | 73.984 | 73.65% | 411 | <6.0 | 40.52C | 0.957 |
12.175V | 5.038V | 3.308V | 5.06V | 100.455 | 50.92C | 115.11V | ||||
CL4 | 82.573A | 0A | 0A | 0A | 999.941 | 88.224% | 1254 | 36.1 | 45.32C | 0.993 |
12.109V | 5.027V | 3.32V | 5.02V | 1133.418 | 57.25C | 114.86V |
Load regulation is tight on all major rails but 3.3V.
Ripple Suppression
Test | 12V | 5V | 3.3V | 5VSB | Pass/Fail |
10% Load | 6.7 mV | 6.5 mV | 4.3 mV | 4.9 mV | Pass |
20% Load | 8.2 mV | 5.2 mV | 4.1 mV | 5.3 mV | Pass |
30% Load | 14.1 mV | 5.1 mV | 5.1 mV | 5.2 mV | Pass |
40% Load | 11.7 mV | 11.5 mV | 15.9 mV | 5.6 mV | Pass |
50% Load | 10.4 mV | 6.6 mV | 5.1 mV | 6.7 mV | Pass |
60% Load | 10.6 mV | 8.1 mV | 5.9 mV | 6.1 mV | Pass |
70% Load | 11.2 mV | 12.2 mV | 8.0 mV | 6.1 mV | Pass |
80% Load | 11.7 mV | 7.4 mV | 10.0 mV | 6.7 mV | Pass |
90% Load | 13.0 mV | 8.3 mV | 9.4 mV | 8.4 mV | Pass |
100% Load | 19.1 mV | 8.9 mV | 10.2 mV | 9.2 mV | Pass |
110% Load | 21.5 mV | 8.6 mV | 10.9 mV | 9.6 mV | Pass |
Crossload 1 | 9.8 mV | 8.7 mV | 11.1 mV | 7.4 mV | Pass |
Crossload 2 | 10.0 mV | 7.8 mV | 4.1 mV | 6.8 mV | Pass |
Crossload 3 | 7.3 mV | 5.8 mV | 11.1 mV | 6.9 mV | Pass |
Crossload 4 | 19.9 mV | 6.8 mV | 6.0 mV | 8.0 mV | Pass |
Ripple suppression is good on all rails.
Pages:
Would this be a better choice than the Super Flower VII Gold?
Hi! Thanks for your reply! I appreciate it!
Very impressive work! Thank you very much! 🙂
I was wondering if you heard anything about the Straight Power 12 from be quiet? I have barely heard about this unit and I was hesitating between the Straight Power 12, a Corsair RMx/e or a NZXT C Gold for an RTX 4070 ti Super + i5-14600K system (850 – 1000W range).
Thank you againt!
I haven’t checked it so far, SP 12.
Hi! Thanks for your reply! I appreciate it!