Enermax Revolution D.F.12 750W PSU Review

Protection Features

OCP (Cold @ 28°C) 12V: 91.2A (146.15%), 12.099V
5V: 25.4A (127%), 4.997V
3.3V: 25.2A (126%), 3.283V
5VSB: 5A (166.67%), 4.907V
OCP (Hot @ 42°C) 12V: 74A (118.59%), 12.112V
5V: 23.4A (117%), 4.998V
3.3V: 24.7A (123.5%), 3.283V
5VSB: 4.9A (163.33%),4.935V
OPP (Cold @ 28°C) 1103.8W (147.41%)
OPP (Hot @ 43°C) 896.25W (119.69%)
OTP ✓ (150°C @ heat sink)
SCP 12V to Earth: ✓
5V to Earth: ✓
3.3V to Earth: ✓
5VSB to Earth: ✓
-12V to Earth: ✓
PWR_OK Proper Operation
NLO
Fan Failure Protection
SIP Surge: MOV
Inrush: NTC Thermistor & Bypass relay

The protection features are correctly set, and contrary to the 850W model, the OCP and OPP triggering points are far under hot and cold conditions. The only exception is the 3.3V rail, where the OCP triggering point should be lower at high temperatures. The OCP and OPP triggering points under high temperatures are notably lower, effectively protecting the PSU. All the other major protection features are present and work well.