DeepCool PN750D ATX v3.1 PSU Review

Hold Up Time

The hold-up time doesn’t exceed 17ms, and the power ok signal’s hold-up time is lower than 16ms. This would be a problem if the PSU claimed ATX v3.0 compatibility but not an issue for the ATX v3.1 spec, which is looser in this section.

Inrush Current

The inrush currents are at normal levels.

Timings

The PSU supports Alternative Low Power Modes. The T1 period is extremely low!

Pages ( 6 of 11 ): « Previous12345 6 7891011Next »

Related Posts

5 thoughts on “DeepCool PN750D ATX v3.1 PSU Review

  1. Probably just a typographical error. I suggest you correct the amperage on the 12 volt rail from 6,205 amps to 62.5 amps.

    I agree with your review. The psu may be budget oriented but it does need a few improvements.