DeepCool PN750D ATX v3.1 PSU Review

Transient Response

20% Load – 20ms

Voltage Before After Change Pass/Fail
12V 12.048V 11.711V 2.80% Pass
5V 5.041V 4.914V 2.51% Pass
3.3V 3.349V 3.189V 4.78% Pass
5VSB 5.046V 4.968V 1.54% Pass

50% Load -20ms

Voltage Before After Change Pass/Fail
12V 12.028V 11.878V 1.25% Pass
5V 5.030V 4.922V 2.15% Pass
3.3V 3.338V 3.170V 5.04% Pass
5VSB 4.993V 4.920V 1.46% Pass

The transient response is mediocre overall.

Transient Response ATX v3.x Tests

The PSU passes all ATX v3.1 transient response tests, but the 12V rail drops low in the 200% load test.

The 12V rail doesn’t perform well, dropping its voltage low.

Pages ( 5 of 11 ): « Previous1234 5 67891011Next »

Related Posts

5 thoughts on “DeepCool PN750D ATX v3.1 PSU Review

  1. Probably just a typographical error. I suggest you correct the amperage on the 12 volt rail from 6,205 amps to 62.5 amps.

    I agree with your review. The psu may be budget oriented but it does need a few improvements.

Leave a Reply

Your email address will not be published. Required fields are marked *