Deepcool PL800D: The most affordable ATX v3.1 PSU!

Protection Features

OCP (Cold @ 27°C) 12V: 87A (130.83%), 11.912V
5V: 31.2A (156%), 5.05V
3.3V: 30.6A (153%), 3.285V
5VSB: 4A (133.33%), 4.913V
OCP (Hot @ 44°C) 12V: 75.8A (113.98%), 11.921V
5V: 30.2A (151%), 5.052V
3.3V: 29.9A (149.5%), 3.286V
5VSB: 3.9A (130%), 4.913V
OPP (Cold @ 28°C) 1022.27W (127.78%)
OPP (Hot @ 43°C) 896.78W (112.1%)
OTP ✓ (110°C @ +12V heat sink)
SCP 12V to Earth: ✓
5V to Earth: ✓
3.3V to Earth: ✓
5VSB to Earth: ✓
-12V to Earth: ✓
PWR_OK Proper operation
NLO
Fan Failure Protection
SIP Surge: MOV
Inrush: NTC Thermistor & Bypass relay

The 12V rail’s over current protection is conservatively set, especially under hot conditions where the triggering point drops notably. The same goes for OPP. On the other hand, the minor rails have sky-high OCP triggering points. There is no need for such high OCP on the minor rails.

Pages ( 8 of 11 ): « Previous1234567 8 91011Next »

Related Posts

Leave a Reply

Your email address will not be published. Required fields are marked *