Cooler Master GX III 750W ATX v3.0 PSU Review

Protection Features

OCP (Cold @ 19°C) 12V: 77A (123.2%), 11.975V
5V: 25.8A (129%), 4.991V
3.3V: 25.6A (128%), 3.317V
5VSB: 6.1A (203.33%), 4.799V
OCP (Hot @ 37°C) 12V: 76.8A (122.88%), 11.977V
5V: 25.5A (127.5%), 4.993V
3.3V: 25.7A (128.5%), 3.317V
5VSB: 6A (200%), 4.805V
OPP (Cold @ 20°C) 1032.60W (137.68%)
OPP (Hot @ 39°C) 1001.59W (133.55%)
OTP ✓ (143°C @ +12V heat sink)
SCP 12V to Earth: ✓
5V to Earth: ✓
3.3V to Earth: ✓
5VSB to Earth: ✓
-12V to Earth: ✓
PWR_OK Proper operation
NLO
Fan Failure Protection
SIP Surge: MOV
Inrush: NTC Thermistor & Bypass relay

The 12V rail is conservatively set, but having the same triggering point under cold and hot conditions is incorrect. Thankfully, this is not the case for over power protection, where the triggering point is notably lower at high temperatures. Moreover, the minor rails have been correctly set over current points, but like the 12V rail, the triggering points are similar under cold and hot conditions. Finally, all other essential protection features are present and work well.