Normalized Noise Tests
For these tests, I set the fan to speeds with noise output at the following predefined levels: 20/25/30/35/40/45 dBA. I skip the corresponding tests if the fan under the test cannot reach some noise levels. The speeds shown in the graph below are measured with the fan in a clear space inside my hemi-anechoic chamber without any obstacles. I set these speeds on the Longwin machine, but they slightly change because of the variable conditions that the device applies.
20 dBA Noise Output
- Low speed
- Top airflow
- Low static pressure
- Average power consumption
25 dBA Noise Output
- Low speed
- Top airflow
- Low static pressure
- Average power consumption
30 dBA Noise Output
- Low speed
- Top airflow
- Low static pressure
- Low power consumption
Pages:
Hi juste to remind you about the NF-A14 industrialPPC 😅 and if you can ask Silverstone for review the new FHS 140X 😊
.
will do! As for Noctua, they don’t talk to me anymore. I asked for these fans already, they didn’t send them after the G2’s reviews.