Load Regulation
Test | 12V | 5V | 3.3V | 5VSB | DC/AC (Watts) | Efficiency | Fan Speed (RPM) | PSU Noise (dB[A]) | Temps (In/Out) | PF/AC Volts |
10% | 5.191A | 1.979A | 2.009A | 0.994A | 85.007 | 86.468% | 914 | 21.5 | 40.10C | 0.982 |
12.215V | 5.055V | 3.285V | 5.031V | 98.309 | 44.31C | 115.15V | ||||
20% | 11.472A | 2.969A | 3.016A | 1.194A | 169.974 | 90.191% | 918 | 21.6 | 40.64C | 0.989 |
12.122V | 5.053V | 3.282V | 5.025V | 188.457 | 45.19C | 115.13V | ||||
30% | 18.075A | 3.465A | 3.522A | 1.396A | 254.99 | 91.065% | 921 | 21.6 | 41.06C | 0.992 |
12.112V | 5.051V | 3.28V | 5.017V | 280.009 | 46.14C | 115.11V | ||||
40% | 24.680A | 3.962A | 4.029A | 1.597A | 340.084 | 91.024% | 924 | 21.8 | 41.81C | 0.99 |
12.110V | 5.049V | 3.277V | 5.009V | 373.619 | 47.36C | 115.08V | ||||
50% | 30.810A | 4.956A | 5.042A | 1.8A | 425.11 | 90.697% | 929 | 21.8 | 42.09C | 0.991 |
12.158V | 5.046V | 3.273V | 5.002V | 468.716 | 48.11C | 115.05V | ||||
60% | 37.014A | 5.951A | 6.057A | 2.001A | 509.63 | 90.068% | 932 | 21.9 | 42.80C | 0.992 |
12.153V | 5.043V | 3.27V | 4.995V | 565.825 | 49.37C | 115.03V | ||||
70% | 43.292A | 6.946A | 7.074A | 2.206A | 594.976 | 89.303% | 1323 | 33.6 | 43.39C | 0.993 |
12.147V | 5.04V | 3.266V | 4.988V | 666.245 | 50.45C | 115V | ||||
80% | 49.592A | 7.944A | 8.094A | 2.309A | 679.804 | 88.5% | 1635 | 39.2 | 43.69C | 0.994 |
12.137V | 5.036V | 3.262V | 4.982V | 768.142 | 51.79C | 114.98V | ||||
90% | 56.289A | 8.445A | 8.593A | 2.412A | 765.234 | 87.703% | 1960 | 45.1 | 44.84C | 0.995 |
12.129V | 5.033V | 3.258V | 4.976V | 872.538 | 53.89C | 114.95V | ||||
100% | 62.723A | 8.947A | 9.124A | 3.028A | 850.066 | 86.809% | 2215 | 47.7 | 45.81C | 0.995 |
12.122V | 5.03V | 3.255V | 4.954V | 979.233 | 55.88C | 114.91V | ||||
110% | 69.034A | 9.948A | 10.243A | 3.029A | 934.63 | 85.845% | 2399 | 49.3 | 46.85C | 0.996 |
12.115V | 5.026V | 3.251V | 4.952V | 1088.732 | 57.75C | 114.88V | ||||
CL1 | 0.115A | 14.339A | 14.581A | 0A | 121.308 | 83.357% | 944 | 22.3 | 40.84C | 0.988 |
12.159V | 5.035V | 3.271V | 5.085V | 145.529 | 46.36C | 115.14V | ||||
CL2 | 0.115A | 21.821A | 0A | 0A | 111.394 | 81.315% | 943 | 22.3 | 41.13C | 0.985 |
12.167V | 5.041V | 3.29V | 5.12V | 136.99 | 48.20C | 115.14V | ||||
CL3 | 0.114A | 0A | 22.207A | 0A | 73.995 | 75.937% | 922 | 21.7 | 40.12C | 0.982 |
12.219V | 5.057V | 3.269V | 5.053V | 97.443 | 49.17C | 115.16V | ||||
CL4 | 70.098A | 0.001A | 0.005A | 0.001A | 849.807 | 87.536% | 2087 | 45.7 | 45.56C | 0.995 |
12.123V | 5.05V | 3.268V | 5.038V | 970.819 | 56.53C | 114.91V |
Load regulation is tight at 5V only, while it is over 1% on all other rails.
Ripple Suppression
Test | 12V | 5V | 3.3V | 5VSB | Pass/Fail |
10% Load | 7.0 mV | 5.8 mV | 5.4 mV | 5.6 mV | Pass |
20% Load | 13.6 mV | 6.2 mV | 7.9 mV | 5.9 mV | Pass |
30% Load | 12.7 mV | 7.4 mV | 11.1 mV | 7.3 mV | Pass |
40% Load | 14.1 mV | 9.5 mV | 15.8 mV | 8.1 mV | Pass |
50% Load | 16.8 mV | 10.6 mV | 16.8 mV | 8.6 mV | Pass |
60% Load | 18.8 mV | 11.2 mV | 19.5 mV | 9.4 mV | Pass |
70% Load | 21.5 mV | 13.0 mV | 22.7 mV | 10.7 mV | Pass |
80% Load | 23.8 mV | 15.1 mV | 29.0 mV | 12.5 mV | Pass |
90% Load | 26.6 mV | 16.4 mV | 32.0 mV | 13.5 mV | Pass |
100% Load | 33.7 mV | 20.4 mV | 37.1 mV | 17.5 mV | Pass |
110% Load | 37.0 mV | 21.9 mV | 40.2 mV | 17.6 mV | Pass |
Crossload 1 | 27.2 mV | 9.2 mV | 13.4 mV | 7.5 mV | Pass |
Crossload 2 | 14.7 mV | 8.9 mV | 6.0 mV | 6.1 mV | Pass |
Crossload 3 | 6.3 mV | 5.0 mV | 12.7 mV | 5.3 mV | Pass |
Crossload 4 | 33.6 mV | 16.1 mV | 31.9 mV | 14.0 mV | Pass |
Ripple suppression is decent on all rails but 5VSB, where it is not that good.
Pages:
Thank you for the review. What kind of problem could it be if it drops below 3.14V? Thanks for the answer in advance.
It will apply high stress to the corresponding DC-DC converter that expects 3.3V at its input. This is why the ATX spec sets as the lowest limit the 3.14V level.
Thank you for the information. Then I’ll go back to the beginning and start looking for a new psu. I benefit a lot from your articles. Thank you.