Protection Features
OCP (Cold @ 28°C) | 12V: 124A (148.86%), 11.913V 5V: 23.4A (117%), 4.91V 3.3V: 24.1A (120.5%), 3.269V 5VSB: 4.9A (163.33%), 5.03V |
OCP (Hot @ 45°C) | 12V: 121.8A (146.22%), 11.92V 5V: 22.1A (110.5%), 4.895V 3.3V: 22.2A (111%), 3.268V 5VSB: 4.8A (160%), 5.03V |
OPP (Cold @ 29°C) | 1487.18W (148.72%) |
OPP (Hot @ 44°C) | 1450.67W (145.07%) |
OTP | ✓ (107°C @ secondary side) |
SCP | 12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓ |
PWR_OK | Accurate but lower than 16ms |
NLO | ✓ |
Fan Failure Protection | ✗ |
SIP | Surge: MOV Inrush: NTC Thermistor & Bypass relay |
The 12V rail’s OCP triggering point is set sky-high, and the same goes for over power protection. Moreover, the differences in the respective triggering points between hot and cold conditions are low. On the other hand, the minor rails are conservatively set, and their triggering points drop notably lower at high temperatures.
The PWR_OK signal is lower than 16ms, which was the ATX v3.0 spec’s lowest limit, but it meets the corresponding low limit of the ATX v3.1 spec, which is 11ms.