Sharkoon Rebel P20 SFX 1000W ATX v3.1 PSU Review

Protection Features

OCP (Cold @ 28°C) 12V: 124A (148.86%), 11.913V
5V: 23.4A (117%), 4.91V
3.3V: 24.1A (120.5%), 3.269V
5VSB: 4.9A (163.33%), 5.03V
OCP (Hot @ 45°C) 12V: 121.8A (146.22%), 11.92V
5V: 22.1A (110.5%), 4.895V
3.3V: 22.2A (111%), 3.268V
5VSB: 4.8A (160%), 5.03V
OPP (Cold @ 29°C) 1487.18W (148.72%)
OPP (Hot @ 44°C) 1450.67W (145.07%)
OTP ✓ (107°C @ secondary side)
SCP 12V to Earth: ✓
5V to Earth: ✓
3.3V to Earth: ✓
5VSB to Earth: ✓
-12V to Earth: ✓
PWR_OK Accurate but lower than 16ms
NLO
Fan Failure Protection
SIP Surge: MOV
Inrush: NTC Thermistor & Bypass relay

The 12V rail’s OCP triggering point is set sky-high, and the same goes for over power protection. Moreover, the differences in the respective triggering points between hot and cold conditions are low. On the other hand, the minor rails are conservatively set, and their triggering points drop notably lower at high temperatures.

The PWR_OK signal is lower than 16ms, which was the ATX v3.0 spec’s lowest limit, but it meets the corresponding low limit of the ATX v3.1 spec, which is 11ms.