Protection Features
OCP (Cold @ 29°C) | 12V: 97A (137.01%), 12.136V 5V: 29.5A (147.5%), 4.987V 3.3V: 28.3A (141.5%), 3.315V 5VSB: 6.6A (220%), 4.899V |
OCP (Hot @ 44°C) | 12V: 98.2A (138.7%), 12.147V 5V: 29.5A (147.5%), 4.977V 3.3V: 28.4A (142%), 3.316V 5VSB: 6.6A (220%), 4.905V |
OPP (Cold @ 28°C) | 1047.65W (123.25%) |
OPP (Hot @ 41°C) | 1057.64W (124.43%) |
OTP | ✓ (160°C @ secondary side) |
SCP | 12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓ |
PWR_OK | Proper operation |
NLO | ✓ |
Fan Failure Protection | ✗ |
SIP | Surge: MOV Inrush: NTC Thermistor & Bypass relay |
The 12V OCP triggering points are pretty high, and to make matters worse, the hot triggering point is higher than the cold one! The OPP triggering points are conservative, but the hot triggering point is higher than the cold one. Lastly, the minor rails have high OCP triggering points, which are identical under cold and hot conditions, which is incorrect.
Pages:
OEM not is andyson,It should dongguan UNEEC (cheng ming) Technology