Load Regulation
Test | 12V | 5V | 3.3V | 5VSB | DC/AC (Watts) | Efficiency | Fan Speed (RPM) | PSU Noise (dB[A]) | Temps (In/Out) | PF/AC Volts |
10% | 4.376A | 1.981A | 1.979A | 0.988A | 75.002 | 83.433% | 0 | <6.0 | 44.45C | 0.954 |
12.205V | 5.048V | 3.334V | 5.061V | 89.895 | 40.36C | 114.89V | ||||
20% | 9.755A | 2.972A | 2.972A | 1.191A | 149.942 | 88.192% | 0 | <6.0 | 45.01C | 0.975 |
12.203V | 5.048V | 3.331V | 5.039V | 170.016 | 40.73C | 114.86V | ||||
30% | 15.495A | 3.467A | 3.469A | 1.395A | 224.949 | 89.994% | 0 | <6.0 | 45.95C | 0.982 |
12.191V | 5.047V | 3.33V | 5.018V | 249.957 | 41.21C | 114.84V | ||||
40% | 21.241A | 3.964A | 3.967A | 1.601A | 300.038 | 90.395% | 0 | <6.0 | 46.70C | 0.984 |
12.186V | 5.046V | 3.328V | 4.998V | 331.921 | 41.66C | 114.8V | ||||
50% | 26.580A | 4.956A | 4.962A | 1.809A | 374.484 | 90.099% | 0 | <6.0 | 47.79C | 0.986 |
12.189V | 5.045V | 3.326V | 4.977V | 415.637 | 42.28C | 114.79V | ||||
60% | 31.977A | 5.952A | 5.963A | 2A | 449.318 | 89.653% | 787 | 15.2 | 42.86C | 0.986 |
12.183V | 5.041V | 3.321V | 4.959V | 501.171 | 48.88C | 114.75V | ||||
70% | 37.387A | 6.949A | 6.968A | 2.228A | 524.32 | 89.222% | 786 | 15.1 | 43.26C | 0.986 |
12.175V | 5.038V | 3.316V | 4.938V | 587.656 | 50.35C | 114.72V | ||||
80% | 42.863A | 7.941A | 7.971A | 2.334A | 599.676 | 88.794% | 784 | 15.1 | 44.97C | 0.987 |
12.175V | 5.036V | 3.312V | 4.928V | 675.222 | 53.02C | 114.7V | ||||
90% | 48.598A | 8.438A | 8.459A | 2.442A | 674.538 | 88.046% | 777 | 14.8 | 45.45C | 0.988 |
12.182V | 5.036V | 3.31V | 4.914V | 766.116 | 54.58C | 114.67V | ||||
100% | 54.140A | 8.934A | 8.976A | 3.078A | 749.757 | 87.141% | 772 | 14.6 | 46.11C | 0.989 |
12.192V | 5.036V | 3.309V | 4.873V | 860.398 | 56.17C | 114.64V | ||||
110% | 59.590A | 9.929A | 10.074A | 3.079A | 824.78 | 86.235% | 1351 | 32.8 | 46.98C | 0.99 |
12.191V | 5.035V | 3.305V | 4.872V | 956.435 | 57.95C | 114.61V | ||||
CL1 | 0.114A | 11.913A | 11.962A | 0A | 101.296 | 81.431% | 789 | 15.3 | 41.28C | 0.967 |
12.240V | 5.053V | 3.319V | 5.113V | 124.395 | 46.79C | 114.87V | ||||
CL2 | 0.113A | 19.771A | 0A | 0A | 101.351 | 79.978% | 1360 | 33.0 | 40.37C | 0.968 |
12.214V | 5.056V | 3.326V | 5.116V | 126.724 | 47.46C | 114.87V | ||||
CL3 | 0.113A | 0A | 19.9A | 0A | 67.398 | 74.304% | 1360 | 33.0 | 40.41C | 0.955 |
12.200V | 5.039V | 3.317V | 5.115V | 90.705 | 49.51C | 114.89V | ||||
CL4 | 61.629A | 0A | 0A | 0A | 749.611 | 88.146% | 1346 | 32.7 | 42.78C | 0.989 |
12.163V | 5.035V | 3.322V | 5.065V | 850.403 | 53.76C | 114.64V |
Load regulation is within 1% on all major rails. It is loose at 5VSB, but it doesn’t matter much in this rail as long as it is within spec.
Ripple Suppression
Test | 12V | 5V | 3.3V | 5VSB | Pass/Fail |
10% Load | 12.4 mV | 11.2 mV | 9.7 mV | 16.0 mV | Pass |
20% Load | 11.8 mV | 11.6 mV | 10.2 mV | 16.9 mV | Pass |
30% Load | 12.3 mV | 11.1 mV | 10.3 mV | 16.6 mV | Pass |
40% Load | 11.8 mV | 11.0 mV | 11.1 mV | 16.8 mV | Pass |
50% Load | 11.6 mV | 13.2 mV | 12.1 mV | 17.7 mV | Pass |
60% Load | 12.1 mV | 11.6 mV | 11.3 mV | 18.9 mV | Pass |
70% Load | 12.6 mV | 11.9 mV | 11.8 mV | 20.0 mV | Pass |
80% Load | 12.8 mV | 12.6 mV | 13.8 mV | 19.3 mV | Pass |
90% Load | 12.0 mV | 13.0 mV | 14.2 mV | 20.4 mV | Pass |
100% Load | 15.5 mV | 13.9 mV | 16.0 mV | 23.9 mV | Pass |
110% Load | 15.4 mV | 13.6 mV | 16.8 mV | 23.6 mV | Pass |
Crossload 1 | 11.6 mV | 12.1 mV | 12.3 mV | 15.8 mV | Pass |
Crossload 2 | 12.6 mV | 14.9 mV | 10.5 mV | 15.9 mV | Pass |
Crossload 3 | 11.5 mV | 11.3 mV | 13.6 mV | 13.2 mV | Pass |
Crossload 4 | 15.2 mV | 13.0 mV | 14.5 mV | 19.4 mV | Pass |
Ripple suppression is good, especially at 12V.
Pages: