Protection Features
OCP (Cold @ 27°C) | 12V: 130.4A (156.54%), 12.04V 5V: 30.8A (154%), 4.971V 3.3V: 29.6A (148%), 3.288V 5VSB: 6.3A (210%), 4.87V |
OCP (Hot @ 41°C) | 12V: 122.6A (147.18%), 12.076V 5V: 30.8A (154%), 4.973V 3.3V: 29.5A (147.5%), 3.294V 5VSB: 6.2A (206.67%), 4.867V |
OPP (Cold @ 28°C) | 1338.1W (133.81%) |
OPP (Hot @ 42°C) | 1183.09W (118.31%) |
OTP | ✓ (150°C @ +12V heat sink) |
SCP | 12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓ |
PWR_OK | Proper operation |
NLO | ✓ |
Fan Failure Protection | ✗ |
SIP | Surge: MOV Inrush: NTC Thermistor & Bypass relay |
The 12V OCP triggering points are pretty high—at least the difference between cold and hot conditions is large enough. The OPP triggering points are more conservative, and under hot conditions, the OPP’s point drops below 120%. Lastly, the minor rails have high OCP triggering points, which are identical under cold and hot conditions, which is incorrect.