Protection Features
OCP (Cold @ 27°C) | 12V: 129A (123.92%), 11.96V 5V: 28.3A (128.64%), 5.014V 3.3V: 30A (136.36%), 3.324V 5VSB: 4.8A (160%), 4.91V |
OCP (Hot @ 40°C) | 12V: – 5V: 27.5A (125%), 4.993V 3.3V: 29.6A (134.55%), 3.324V 5VSB: 4.8A (160%), 4.908V |
OPP (Cold @ 29°C) | 1521.54W (121.72%) |
OPP (Hot @ 42°C) | 1443.49W (115.48%) |
OTP | – |
SCP | 12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓ |
PWR_OK | Accurate but lower than 16ms |
NLO | ✓ |
Fan Failure Protection | ✗ |
SIP | Surge: MOV Inrush: NTC Thermistor & Bypass relay |
After the 5V OCP evaluation at high temperatures, the unit broke down, so I couldn’t finish the 12V OCP at high temperatures and the over temperature protection evaluation. Although OCP at 5V isn’t that high, still the platform couldn’t take it. This is why I insist for lower OCP triggering points under high temperatures, especially on the minor rails where usually OCP is set sky-high.