Montech Titan Gold 850W PSU Review

Protection Features

OCP (Cold @ 26°C) 12V: 84.8A (119.77%), 12.053V
5V: 26.7A (121.36%), 5.013V
3.3V: 26.3A (119.55%), 3.264V
5VSB: 5.1A (170%), 4.971V
OCP (Hot @ 33°C) 12V: 85.8A (121.19%), 12.063V
5V: 26.6A (120.91%), 5.014V
3.3V: 26.3A (119.55%), 3.262V
5VSB: 5.1A (170%), 4.971V
OPP (Cold @ 27°C) 1072.56W (126.18%)
OPP (Hot @ 37°C) 1072.63W (126.19%)
OTP ✓ (158°C @ 12V secondary side)
SCP 12V to Earth: ✓
5V to Earth: ✓
3.3V to Earth: ✓
5VSB to Earth: ✓
-12V to Earth: ✓
PWR_OK Proper Operation
NLO
SIP Surge: MOV
Inrush: NTC Thermistor & Bypass Relay

OCP on all rails and OPP are conservatively set, but normally I expect lower triggering points at higher operating temperatures, mostly at OPP.  Nonetheless, all triggering points are well below 130%, and the platform is strong enough to handle the increased loads even at high temperatures. Lastly, the other protection features are present and work well.