Green Medel GP1000B-EDGE ATX v3.1 PSU Review

Load Regulation

Test 12V 5V 3.3V 5VSB DC/AC (Watts) Efficiency Fan Speed (RPM) PSU Noise (dB[A]) Temps (In/Out) PF/AC Volts
10% 6.486A 1.981A 1.98A 0.993A 100.025 86.432% 0 <6.0 49.85°C 0.974
12.089V 5.048V 3.334V 5.035V 115.74 40.33°C 115.15V
20% 13.992A 2.974A 2.973A 1.195A 199.981 90.747% 0 <6.0 49.62°C 0.991
12.084V 5.046V 3.331V 5.024V 220.382 40.91°C 115.13V
30% 21.857A 3.471A 3.472A 1.396A 300.041 91.855% 416 <6.0 41.29°C 0.997
12.078V 5.043V 3.327V 5.014V 326.641 50.48°C 115.1V
40% 29.729A 3.97A 3.972A 1.599A 399.871 92.007% 683 19.1 41.54°C 0.996
12.064V 5.04V 3.324V 5.005V 434.59 48.59°C 115.06V
50% 37.253A 4.966A 4.972A 1.803A 499.639 91.881% 709 20.9 42.31°C 0.996
12.056V 5.036V 3.32V 4.994V 543.778 49.76°C 115.04V
60% 44.846A 5.963A 5.972A 2.001A 600.177 91.607% 795 25.3 42.61°C 0.996
12.050V 5.033V 3.316V 4.983V 655.116 50.37°C 115.01V
70% 52.394A 6.961A 6.976A 2.213A 699.975 90.447% 979 33 43.18°C 0.997
12.041V 5.03V 3.313V 4.971V 773.928 51.12°C 114.98V
80% 60.006A 7.96A 7.98A 2.318A 800.02 89.789% 1379 41.4 43.95°C 0.997
12.034V 5.027V 3.309V 4.962V 891.017 50.46°C 114.95V
90% 67.958A 8.462A 8.472A 2.423A 899.796 89.32% 1498 43.3 44.47°C 0.997
12.027V 5.025V 3.306V 4.953V 1007.363 51.37°C 114.92V
100% 75.696A 8.961A 8.994A 3.04A 999.686 88.875% 1501 43.3 45.85°C 0.998
12.022V 5.023V 3.303V 4.935V 1124.866 58°C 114.89V
110% 83.379A 9.963A 10.095A 3.045A 1100.392 87.977% 1754 47 46.28°C 0.998
12.018V 5.02V 3.299V 4.927V 1250.823 60.49°C 114.86V
CL1 0.118A 14.355A 14.349A 0A 121.333 82.842% 426 <6.0 41.16°C 0.982
12.077V 5.03V 3.324V 5.044V 146.487 53.98°C 115.17V
CL2 0.116A 23.902A 0A 0.001A 121.414 81.002% 848 27.6 40.05°C 0.984
12.082V 5.021V 3.338V 5.051V 149.885 52.08°C 115.17V
CL3 0.116A 0A 23.861A 0A 80.608 75.376% 875 29.5 40.18°C 0.973
12.066V 5.054V 3.319V 5.045V 106.944 52.05°C 115.18V
CL4 83.147A 0A 0A 0A 1000.524 89.005% 1680 46.5 45.53°C 0.998
12.033V 5.038V 3.311V 4.999V 1124.078 59.16°C 114.89V

Load regulation is only tight (within 1%) at 5V. At 12V, at light loads (up to 80W), the rail’s voltage is kept low and increases at 100W. This affects the load regulation on this rail (see graph below).

Ripple Suppression

Test 12V 5V 3.3V 5VSB Pass/Fail
10% Load 12.1 mV 7.0 mV 5.0 mV 17.6 mV Pass
20% Load 12.8 mV 7.5 mV 4.5 mV 17.0 mV Pass
30% Load 14.6 mV 7.7 mV 4.3 mV 18.0 mV Pass
40% Load 12.8 mV 7.8 mV 4.5 mV 19.1 mV Pass
50% Load 12.6 mV 8.1 mV 4.6 mV 19.6 mV Pass
60% Load 13.4 mV 9.0 mV 5.1 mV 20.0 mV Pass
70% Load 15.7 mV 8.7 mV 5.7 mV 21.9 mV Pass
80% Load 14.7 mV 9.3 mV 8.4 mV 22.2 mV Pass
90% Load 15.2 mV 9.4 mV 8.7 mV 22.8 mV Pass
100% Load 24.8 mV 11.1 mV 9.9 mV 26.9 mV Pass
110% Load 25.8 mV 12.1 mV 11.0 mV 27.2 mV Pass
Crossload 1 16.0 mV 11.9 mV 9.3 mV 20.1 mV Pass
Crossload 2 11.3 mV 15.0 mV 5.4 mV 18.2 mV Pass
Crossload 3 9.6 mV 8.4 mV 12.0 mV 17.5 mV Pass
Crossload 4 25.5 mV 8.8 mV 7.3 mV 25.4 mV Pass

Ripple suppression is good.