Protection Features
OCP (Cold @ 25.9°C) | 12V: 104.60A (147.74%), 12.015V 5V: 31.8A (132.50%), 4.993V 3.3V: 31.5A (131.25%), 3.296V 5VSB: 5.5A (183.33%), 4.908V |
OCP (Hot @ 41.9°C) | 12V: 94.60A (133.62%), 12.034V 5V: 31.7A (132.08%), 4.995V 3.3V: 31.2A (130.00%), 3.301V 5VSB: 5.4A (180.00%), 4.903V |
OPP (Cold @ 26.5°C) | 1232.68W (145.02%) |
OPP (Hot @ 41.9°C) | 1103.62W (129.84%) |
OTP | ✓ (130°C @ Secondary Side) |
SCP | 12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓ |
PWR_OK | Proper Operation |
NLO | ✓ |
Fan Failure Protection | ✗ |
SIP | Surge: MOV Inrush: NTC & Bypass Relay |
The 12V rail’s OCP triggering point is super high at cold conditions but drops notably at high operating temperatures. The minor rails also have high OCP triggering points, allowing them to deliver more than 30A of current. To make matters worse, the difference between the cold and hot operating conditions is low. Lastly, the over power protection’s triggering points are set high, especially in cold conditions, but at least the difference between low and high operating temperatures is increased.