Protection Features
OCP (Cold @ 28°C) | 12V: 83.6A (134.84%), 12.062V 5V: 29A (145%), 5.051V 3.3V: 28.8A (144%), 3.26V 5VSB: 4.1A (164%), 5.025V |
OCP (Hot @ 44°C) | 12V: 82A (132.26%), 12.091V 5V: 28.9A (144.5%), 5.048V 3.3V: 29.3A (146.5%), 3.254V 5VSB: 4A (160%), 5.035V |
OPP (Cold @ 28°C) | 1012.71W (135.03%) |
OPP (Hot @ 42°C) | 964.1W (128.55%) |
OTP | ✓ (163°C @ +12V Heat Sink) |
SCP | 12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓ |
PWR_OK | Proper operation |
NLO | ✓ |
Fan Failure Protection | ✗ |
SIP | Surge: MOV Inrush: NTC Thermistor & Bypass relay |
The 12V rail’s over current protection triggering points are increased, to compensate for the PSU’s low capacity and avoid shut-downs during high power spikes. The difference between hot and cold conditions in the triggering points should be higher, though. The same goes for the minor rails, whose triggering points are high.