Protection Features
OCP (Cold @ 27°C) | 12V: 126.8A (126.8%), 12.182V 5V: 30.5A (152.5%), 5.071V 3.3V: 30.2A (151%), 3.287V 5VSB: 3.8A (126.67%), 4.97V |
OCP (Hot @ 43°C) | 12V: 124.6A (124.6%), 12.192V 5V: 30.4A (152%), 5.075V 3.3V: 30A (150%), 3.287V 5VSB: 3.8A (126.67%), 4.961V |
OPP (Cold @ 26°C) | 1603.08W (133.59%) |
OPP (Hot @ 44°C) | 1439.07W (119.92%) |
OTP | ✓ (133°C @ +12V heat sink) |
SCP | 12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓ |
PWR_OK | Proper operation |
NLO | ✓ |
Fan Failure Protection | ✗ |
SIP | Surge: MOV Inrush: NTC Thermistor & Bypass relay |
The 12V rail’s over current protection is conservatively set under all conditions, which is good, of course. Moreover, the over power protection is properly set, with a large difference between cold and hot conditions, to effectively protect the PSU. Nothing of the above applies to the minor rails, where OCP is sky-high, and the difference in the triggering points between cold and hot conditions is low.