Deepcool PL750D: ATX v3.1 PSU at €69!

Load Regulation

Test 12V 5V 3.3V 5VSB DC/AC (Watts) Efficiency Fan Speed (RPM) PSU Noise (dB[A]) Temps (In/Out) PF/AC Volts
10% 4.437A 1.963A 1.98A 0.998A 75.004 82.448% 1093 25.9 40.26C 0.945
12.036V 5.096V 3.334V 5.009V 90.97 44.45C 115.14V
20% 9.898A 2.946A 2.975A 1.201A 149.968 86.932% 1096 25.9 40.63C 0.971
12.029V 5.094V 3.328V 4.996V 172.513 45.17C 115.12V
30% 15.713A 3.438A 3.474A 1.405A 224.972 88.162% 1099 26.1 41.07C 0.983
12.022V 5.092V 3.325V 4.984V 255.18 46.08C 115.1V
40% 21.542A 3.93A 3.975A 1.61A 300.056 88.261% 1101 26.1 41.72C 0.988
12.016V 5.09V 3.321V 4.971V 339.962 47.23C 115.08V
50% 26.987A 4.915A 4.977A 1.816A 374.592 87.852% 1108 26.5 42.35C 0.991
12.009V 5.087V 3.316V 4.957V 426.393 48.39C 115.06V
60% 32.471A 5.902A 5.983A 2A 449.411 87.128% 1321 31.2 42.75C 0.993
12.001V 5.084V 3.31V 4.944V 515.807 49.27C 115.04V
70% 37.968A 6.891A 6.992A 2.232A 524.501 86.258% 1691 39.5 43.16C 0.994
11.994V 5.081V 3.304V 4.929V 608.068 50.20C 115.02V
80% 43.537A 7.878A 8.004A 2.339A 599.733 85.239% 1959 43.3 43.83C 0.994
11.986V 5.078V 3.298V 4.917V 703.589 52.10C 115.01V
90% 49.445A 8.374A 8.499A 2.446A 674.782 84.083% 2094 44.2 44.70C 0.995
11.978V 5.076V 3.294V 4.906V 802.519 53.80C 114.99V
100% 55.157A 8.869A 9.026A 3.074A 749.972 82.614% 2108 44.5 45.42C 0.995
11.971V 5.074V 3.29V 4.88V 907.812 55.49C 114.96V
110% 60.743A 9.86A 10.14A 3.079A 824.991 81.746% 2112 44.5 46.59C 0.996
11.963V 5.071V 3.284V 4.872V 1009.228 57.47C 114.93V
CL1 0.116A 11.848A 12.036A 0A 101.304 79.859% 1116 26.7 40.49C 0.959
12.027V 5.081V 3.298V 5.024V 126.854 46.40C 115.14V
CL2 0.116A 19.717A 0A 0A 101.398 79.39% 1119 26.8 40.81C 0.958
12.032V 5.072V 3.341V 5.03V 127.72 48.40C 115.14V
CL3 0.116A 0A 20.197A 0A 67.393 73.462% 1092 25.9 39.92C 0.946
12.029V 5.1V 3.268V 5.026V 91.741 49.54C 115.15V
CL4 62.580A 0A 0A 0.001A 749.76 83.783% 2102 44.4 45.88C 0.995
11.981V 5.088V 3.323V 4.982V 894.918 56.38C 114.97V

Load regulation is within 1% at 12V and 5V and close to 1.5% at 3.3V.

Ripple Suppression

Test 12V 5V 3.3V 5VSB Pass/Fail
10% Load 9.4 mV 10.1 mV 6.4 mV 7.4 mV Pass
20% Load 10.1 mV 10.0 mV 6.2 mV 7.3 mV Pass
30% Load 11.9 mV 10.0 mV 6.5 mV 7.2 mV Pass
40% Load 13.4 mV 10.9 mV 6.5 mV 8.1 mV Pass
50% Load 14.8 mV 11.5 mV 7.0 mV 8.5 mV Pass
60% Load 17.9 mV 12.8 mV 7.1 mV 9.1 mV Pass
70% Load 19.4 mV 12.9 mV 7.6 mV 9.6 mV Pass
80% Load 20.3 mV 13.8 mV 13.5 mV 11.0 mV Pass
90% Load 23.3 mV 14.9 mV 14.1 mV 12.3 mV Pass
100% Load 37.8 mV 18.4 mV 17.6 mV 17.1 mV Pass
110% Load 46.3 mV 20.4 mV 19.6 mV 17.9 mV Pass
Crossload 1 15.0 mV 14.2 mV 16.2 mV 7.2 mV Pass
Crossload 2 11.4 mV 15.1 mV 8.5 mV 7.4 mV Pass
Crossload 3 10.3 mV 9.1 mV 18.0 mV 6.1 mV Pass
Crossload 4 40.1 mV 16.4 mV 11.7 mV 12.3 mV Pass

Ripple suppression doesn’t stand out, but it is decent, given the PSU’s budget platform.