Cougar GEX X2 1000W PSU Review

Protection Features

OCP (Cold @ 27°C)

12V: 98.2A (117.89%), 12.076V
5V: 26A (130%), 4.983V
3.3V: 26.3A (131.5%), 3.316V
5VSB: 7A (233.33%), 4.976V

OCP (Hot @ 39°C)

12V: 98.2A (117.89%), 12.077V
5V: 26.5A (132.5%), 4.974V
3.3V: 25.5A (127.5%), 3.315V
5VSB: 7A (233.33%), 4.976V

OPP (Cold @ 29°C)

1271.15W (127.12%)

OPP (Hot @ 39°C)

1271.35W (127.13%)

OTP

✓ (105°C @ 12V Heat Sink)

SCP

12V to Earth: ✓
5V to Earth: ✓
3.3V to Earth: ✓
5VSB to Earth: ✓
-12V to Earth: ✓

PWR_OK

Proper operation

NLO

SIP

Surge: MOV
Inrush: NTC Thermistor & Bypass relay

The OCP triggering points are correctly configured on all rails under cold and hot conditions. The same goes for OPP, but I want a lower OPP triggering point at high temperatures. The other protection features are present and work well.

Pages ( 8 of 11 ): « Previous1234567 8 91011Next »

Related Posts

8 thoughts on “Cougar GEX X2 1000W PSU Review

  1. I’m finding more and more sources confirming that the 12VHPWR connector is actually 450W
    This is a very vile deception :C
    Be careful with this cable.

  2. Ive installed it today and it sucks ass, just sitting in browser it overheats and turns fan on with like 1500rpm to my hearing every 3-5min, also ive looked more closely and this review is so off, on box it says 30% fan start, its 300w, and u show us its 500w, it just cant be true

  3. Hello. This is not the first time I have noticed errors in your article.
    1. Page 1. First write about the depth of 140mm, then as 160mm.
    2. Page 3. APFC MOSFETs and Main Switchers. The text has one name, but a hyperlink to another.
    3. Page 4. Fan Speed (RPM) and PSU Noise (dB[A]) columns. Fan speed and noise do not match page 9.

    I did not read the entire article, but only walked through what interests me.

    1. 1) you were correct I wrote 160mm instead of 140mm. Feel free to shoot me!
      2) the link is correct in APFC, not correct in main switchers. fixed
      3) The page 9 IS NOT THE SAME DATA as page 4. If you had read a bit of the text or noticed the temperatures on the corresponding graphs, you would have seen that.

      You understand that in a review where a full week’s work is needed and around 20K readings have to be obtained (yes thousands) there can be mistakes!
      So I would appreciate a bit tact and understanding from my readers.