Corsair RM850e ATX v3.1 PSU Review

Protection Features

OCP (Normal @ 27.3°C) 12V: 82.62A (116.69%), 12.102V
5V: 29.2A (146.00%), 4.983V
3.3V: 28A (140.00%), 3.262V
5VSB: 4.1A (136.67%), 4.885V
OCP (Hot @ 44.5°C) 12V: 82.42A (116.42%), 12.111V
5V: 28.1A (140.50%), 4.982V
3.3V: 26A (130.00%), 3.27V
5VSB: 4A (133.33%), 4.891V
OPP (Normal @ 28.6°C) 993.81W (116.92%)
OPP (Hot @ 41.3°C) 990.88W (116.57%)
OTP ✓ (125°C @ Heat Sink)
SCP 12V to Earth: ✓
5V to Earth: ✓
3.3V to Earth: ✓
5VSB to Earth: ✓
PWR_OK Proper Operation
NLO
Fan Failure Protection
SIP Surge: MOV
Inrush: NTC & Bypass Relay

The 12V rail’s OCP triggering points are notably below 130% but are identical under cold and hot conditions. Typically, there should be a notable difference between these two conditions. On the minor rails, the difference in the OCP triggering points between the normal and hot temperatures is high enough.

The over power protection has similar triggering points under normal and hot conditions. They are conservative, at least, but still, I would like to see a significant difference between them.