Protection Features

OCP (Normal @ 29.5°C) 12V: 102.40A (122.93%), 12.204V
5V: 28.6A (143.00%), 5.065V
3.3V: 28.4A (142.00%), 3.299V
5VSB: 4.7A (156.67%), 4.937V
OCP (Hot @ 41.9°C) 12V: 98.20A (117.89%), 12.218V
5V: 28A (140.00%), 5.059V
3.3V: 27.5A (137.50%), 3.299V
5VSB: 4.7A (156.67%), 4.916V
OPP (Normal @ 29.3°C) 1339.13W (133.91%)
OPP (Hot @ 41.0°C) 1255.10W (125.51%)
OTP ✓ (115°C @ Secondary Side)
SCP 12V to Earth: ✓
5V to Earth: ✓
3.3V to Earth: ✓
5VSB to Earth: ✓
-12V to Earth: ✓
PWR_OK Proper Operation
NLO
Fan Failure Protection
SIP Surge: MOV
Inrush: NTC & Bypass Relay

OCP at 12V is appropriately set, but I find it too high on the minor rails, mostly at 3.3V, where there is no need for such high Amps. At least, there is enough distance between hot and normal OCP triggering points. Over power protection is also properly set, with enough distance between normal and high temperatures. All other essential protection features are present, and soon enough, I will add more to my test sessions.