Protection Features
OCP (Normal @ 29.5°C) | 12V: 102.40A (122.93%), 12.204V 5V: 28.6A (143.00%), 5.065V 3.3V: 28.4A (142.00%), 3.299V 5VSB: 4.7A (156.67%), 4.937V |
OCP (Hot @ 41.9°C) | 12V: 98.20A (117.89%), 12.218V 5V: 28A (140.00%), 5.059V 3.3V: 27.5A (137.50%), 3.299V 5VSB: 4.7A (156.67%), 4.916V |
OPP (Normal @ 29.3°C) | 1339.13W (133.91%) |
OPP (Hot @ 41.0°C) | 1255.10W (125.51%) |
OTP | ✓ (115°C @ Secondary Side) |
SCP | 12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓ |
PWR_OK | Proper Operation |
NLO | ✓ |
Fan Failure Protection | ✗ |
SIP | Surge: MOV Inrush: NTC & Bypass Relay |
OCP at 12V is appropriately set, but I find it too high on the minor rails, mostly at 3.3V, where there is no need for such high Amps. At least, there is enough distance between hot and normal OCP triggering points. Over power protection is also properly set, with enough distance between normal and high temperatures. All other essential protection features are present, and soon enough, I will add more to my test sessions.
Pages:
Also why did fsp also saving cost on bigger NTCs? 160A+ inrush is very high for my liking 🧐
Too high for my liking*
Imo, pretty overpriced for the build quality it offers.