Protection Features
OCP (Cold @ 26°C) | 12V: 99.2A (140.11%), 12.011V 5V: 29A (145%), 5.031V 3.3V: 30A (150%), 3.329V 5VSB: 4.6A (184%), 4.969V |
OCP (Hot @ 43°C) | 12V: 94.2A (133.05%), 12.008V 5V: 28.8A (144%), 5.052V 3.3V: 29.9A (149.5%), 3.34V 5VSB: 4.3A (172%), 4.974V |
OPP (Cold @ 24°C) | 1109.56W (130.54%) |
OPP (Hot @ 43°C) | 1048.28W (123.33%) |
OTP | ✓ (160°C @ secondary side) |
SCP | 12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓ |
PWR_OK | Proper operation |
NLO | ✓ |
SIP | Surge: MOV Inrush: NTC Thermistor & Bypass relay |
I will give the 12V rail a pass because, at high temperatures, it is close to 130%, but the minor rails have sky-high OCP triggering points, which are not required, especially at 3.3V. Moreover, the over power protection is set correctly; the same goes for over temperature protection.